Intel J2 650 system manual 650 UPS, Specifications, Hardware, Picture to be added here

Models: J2 650

1 78
Download 78 pages 3.56 Kb
Page 72
Image 72

650 UPS

Specifications

Batteries Run Time

2 Hours for the standard 650. Run time will vary

 

depending on the processor used and application load

Power In

19 Volts DC

Power Out

13-16.8 Volts DC, 7.2 amps maximum

Data Interface

RS232 DB9 connector

Batteries Type

2 – 4 18650 cell Li-Ion pack with protection circuit

Battery Life

300 full discharge cycles

Charge Time

3 hours

Charger Type

Smart Microcontroller based

Software

XP Standard Generic UPS driver / J2 Smart UPS driver

Size

6” x 3.1” x 1.7” (152mm x 79mm x 43mm)

Hardware

To install and use the J2 UPS module:

1:Remove the power supply adapter form the base of the unit.

2:Install the UPS module where the power supply was mounted.

3:Connect the power output jack of the UPS to the power in jack of the unit.

4:Connect the Serial cable of the UPS to the serial port you wish to use. *

5:Connect the power supply adapter to the UPS power in jack.

6:Connect the power supply adapter to the mains power. **

7:Configure the Windows UPS drive as shown.

Picture to be added here

*The serial port connection is not needed for Windows CE.

**The mains power should be applied for 3 hours to fully charge the batteries. The unit may be running during this time but will take longer to charge.

650 System Manual (Draft)

72

Version 0.4 August 20, 2008

 

Page 72