Intel® Server Board S5000PAL / S5000XAL TPS

Jumper Block Settings

Note: Normal BMC functionality is disabled with the force BMC update jumper set to the “enabled” position. The server should never be run with the BMC force update jumper set in this position and should only be used when the standard firmware update process fails. This jumper should remain in the default – disabled position when the server is running normally.

6.2BIOS Select Jumper

The jumper block at J3H1, located just to the left of the SSI control panel header, is used to select which BIOS image the system will boot to. Pin 1 on the jumper is identified with a ‘▼’. This jumper should only be moved if you wish to force the BIOS to boot to the secondary bank which may hold a different version of BIOS.

The rolling BIOS feature of the baseboard will automatically alternate the Boot BIOS to the secondary bank in the event the BIOS image in the primary bank is corrupted and cannot boot for any reason.

3

2

3

2

1-2: Force BIOS

to bank 0

J3H1

2-3: System is configured for normal operation (factory default)

TP02305

 

 

Figure 18. BIOS Select Jumper (J3H1)

 

 

 

 

Pins

What happens at system reset…

1-2

Force BIOS to bank 0

 

 

 

2-3

System is configured for normal operation (Default)

 

 

 

 

 

 

Note: When performing a BIOS update procedure, the BIOS select jumper must be set to its default position (pins 2-3).