Light Guided Diagnostics

Intel® Server Board S5000PAL / S5000XAL TPS

7.3DIMM Fault LEDs

The server board provides a memory fault LED for each DIMM slot. The DIMM fault LED is illuminated when the system BIOS disables the specified DIMM after it reaches a specified number of given failures or if specific critical DIMM failures are detected. See the Intel® S5000 Series Chipsets Server Board Family Datasheet for more details.

TP02310

Figure 22. DIMM Fault LED Locations

7.4Processor Fault LED

The server board provides a Processor Fault LED for each of the two processor sockets. These LEDs will illuminate when a CPU is disabled or a CPU configuration error is detected.

CPU 2

CPU 1

TP02311

Figure 23. Processor Fault LED Location

68Revision 1.4

Intel order number: D31979-007

Page 67
Image 67
Intel S5000XAL manual Dimm Fault LEDs, Processor Fault LED