60 Intel® Server System SR1550AL/SR1550ALSAS User’s Guide
9. Connect power to the server board.
10. Install the fan pack. For instructions, see “Installing the Fan Pack”.
11. Install the bridge board.
12. Connect the IDE cable to the connector on the server board.
13. Connect SATA cables to the server board if applicable.
14. Install the PCI riser assembly. For instructions, see “Installing the PCI Riser
Assembly”.
15. Install the processor air duct. For instructions, see “Installing the Processor Air
Duct”.
16. Install the server system cover. For instructions, see “Installing the Server System
Cover”.
17. Plug all peripheral devices and the AC power cable into the server.
Removing the Server Board
1. Observe the safety and ESD precautions at the beginning of this book. See “Safety
Information”.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Chassis
Cover”.
4. Remove the processor air duct. For instructions, see “Removing the Processor Air
Duct”.
5. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser
Assembly”.
6. Disconnect the IDE cable from the server board.
7. Remove the bridge board.
8. Remove the fan pack. For instructions, see “Removing the Fan Pack”.
9. Disconnect power from the server board.
10. Remove the six screws from the server board (see letter “A”) and lift the server
board from the server system (see letter “B”).