5It will eventually load a Welcome screen, asking you to verify the startup directory (C:\NWSERVER). Press Alt F10 to exit the installation. At the console, type Down. The installation exits to the boot drive prompt.

6Insert the SRCU31 NetWare installation diskette created in Step 1 into the A: drive. If your boot drive is C:, then run NWUPDATE.BAT. If your boot drive is other than C:, then create an NWUPDATE subdirectory and copy all the files from A:\DRIVERS into the NWUPDATE subdirectory.

7Remove the diskette from the A: drive and reboot the server. After booting you will be asked to accept the license agreement. Do so and then select Continue with Existing Partition. You are now ready to install NetWare 5 on the Intel Integrated RAID volume.

8Continue with the NetWare installation as normal by following the screen prompts. Select the Block Storage OSM when prompted.

9Reboot the server and install Service Pack 4 or higher. Once the server installation is completed, reboot the server.

10To install the Intel Integrated RAID software (run the Intel Integrated RAID setup) run NWCONFIG.

11Select Product Options, then Install product not listed. It will tell you that it is going to scan the A: drive for installation scripts. Ensure the SRCU31 NetWare Installation diskette is in the floppy drive, press Enter to continue.

12A screen prompt will ask which components (see below) you wish to install. Select the following components and press F10 to continue. See figure below.

BKSTROSM.HAM

HTTP and Winsock Services

RAID Management Agents

Preselect Components

The appropriate files are copied and the AUTOEXEC.NCF and STARTUP.NCF files are modified as necessary.