CV-M4+/M4+CL, CV-M7+/M7+CL
6.4. External Trigger Modes
This camera has 3 external asynchronous trigger modes, which can be set by
1. | Edge | |
2. | Pulse Width Control Mode. TR=2 | Pulse width controlled exposure. |
3.Frame Delay read out mode. TR=3
The trigger can be H synchronous (HC=0) or H
In H synchronous mode, the accumulation will start at the first H (LEN) after the trigger leading edge. In H
In edge
Remark that H is 39.3 ∝sec. But 43.3 ∝sec. when vertical binnig is on.
Restart Continuous Trigger RCT mode (RC=1) can be activated in edge
In pulse width control (PWC) mode the exposure time can be from 2H to ∞. Thermal noise and dark current noise will increase by accumulation time, therefore the exposure time is not recommended to exceed 2 seconds.
Vertical binnig mode (BI=1) can be used in all 3 modes. Only with full scan. (SC=0). Binning will only work on M4+ and M4CL+.
Partial scan (SC=0 through 3) can be used in all 3 modes. Only with binning off. (BI=0).
For all 3 modes smearless read out (SL=1) can be used. At the leading edge of the trigger pulse a dump read out of the vertical ccd register is performed before the accumulation is started. It takes 133 H. It means that the trigger pulse width in PWC and frame delay mode should be >133H. (5.23 msec.)
For frame delay read out (TR=3) the multiple shutter function is available. (ML=1). It can also be combined with smearless read out.
Trigger
Int. HD
Xsub
Accum
3 clk | 157 clk |
| 3.88∝s |
Fig. 19. Accumulation latency time for H a-synchronous trigger.