7.4. RS-232C control

All configuration of the CV-M4+camera is done via the RS-232C port. On the 12 pin Hirose connector, if JP301 is open, or via Camera Link if JP301 is short. The camera can be set up from a PC running terminal emulator software, or using JAI´s camera control software.

Below is the description of the ASCII based short command protocol.

Communication setting.

 

 

 

 

 

 

Baud Rate

9600 bps

 

 

Data Length

8 bit

 

 

Start Bit

1 bit

RS 232C cable

 

Stop Bit

1 bit

 

Parity

None

 

 

Xon/Xoff Control

None

 

Protocol.

 

 

 

 

 

1 CD

 

 

 

 

 

 

 

 

 

 

 

 

4 DTR

 

 

 

 

 

 

 

 

 

 

 

 

6 DSR

9pin

 

 

 

 

 

TXD

 

 

 

 

2 RXD

D-con

 

 

 

 

CAMERA RXD

 

 

 

3 TXD

PCCOM

 

 

 

GND

 

 

5 GND

 

 

PORT

 

 

 

 

 

7 RTS

 

 

 

 

 

 

 

 

 

 

8 CTS

 

 

 

 

 

 

 

 

 

 

 

 

9 CI

 

Transmit setting to camera:

NN=[Parameter]<CR><LF> (NN is any kind of command. Capital or small letters.) The camera answers:

COMPLETE<CR><LF>

To have all communication on the emulator screen, start with:

EB=1<CR><LF>

The camera answers:

COMPLETE<CR><LF>

Transmit request command to camera:

NN?<CR><LF> (NN is any kind of command.)

The camera answers:

NN=[Parameter]<CR><LF>

Transmit the following to have the camera actual setting:

ST?<CR><LF>

The camera answers:

A complete list of the current settings

Transmit the following to have a command list:

HP?<CR><LF>

The camera answers:

A list with all commands and possible settings

Invalid parameters send to camera:

SH=99<CR><LF>

The camera answers:

02 Bad Parameters!!<CR><LF>

When the camera is set in “Off Line” (SW1-10 on rear to Local)

NN=[Parameter]<CR><LF>

The camera answers:

03 Offline!!<CR><LF>

- 23 -