CV-M4+/M4+CL, CV-M7+/M7+CL

5.4. Input and Output Circuits

5.4.1. Video output

 

 

 

 

 

 

 

L

 

 

 

 

 

 

The analogue video output without composite

 

 

 

 

 

 

12

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sync is a 75 DC coupled circuit. It is for test

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68p

 

 

 

 

 

 

only. It can be used for iris control if the

 

 

 

 

 

 

 

 

 

NC

 

 

 

 

 

 

 

 

 

camera is in normal mode. The video black level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is 0.5 volt without termination. The video is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

without composite sync.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Analogue video in partial scan is only valid for the scanned area.

Video

Output

#4/12

GND

Black level

GND

500 mV

Important note on using this signal for iris control.

The signal for iris video output is taken from the video signal after the gain control. If it is used for auto iris control, the digital output video level can only be adjusted with the lens level adjust. The camera gain adjust will only change the working point.

Fig. 5. Video output.

5.4.2. Trigger input Multi Shutter input

The trigger inputs on the 12 pin Hirose connector is AC coupled. To allow a long pulse width, the input circuit is a flip flop, which is toggled by the negative or positive differentiated spikes caused by the falling or rising trigger edges.

The trigger polarity can be changed. Trigger input level 4 V ±2 V.

The trigger-input impedance is 10 k. The trigger inputs can be changed to LVDS or Camera Link input.

Trig input pin #10

 

+5V

15k

 

Multi shut pin #11

 

 

 

100n

1k

TTL

 

68k

 

100k

 

 

10k

 

 

GND

1n

1k

GND

 

 

Fig. 6. Trigger input.

5.4.3. Composite Sync output

On pin #9 on 12 pin HR connector EEN or composite sync can be output. (Command SE). The output circuit is 75

complementary emitter followers. It will deliver a full 5 volt signal.

Output level 4 V from 75. (No termination).

 

 

 

+5V

TTL

 

 

 

100

2

75

#9/12

 

2k2

 

2

 

 

Sync. out

 

 

 

 

 

10k

 

 

GND

 

 

 

Fig. 7. Composite Sync. output

5.4.4. LVDS interface

For LVDS the digital input and output signals follow the EIA 644 standard. It is also called Low Voltage Differential Signal (LVDS). The output differential line driver is NS type DS90C031, and the line receiver is NS type DS90C032.

Typical LVDS output level is ±350 mVolt differential. Typical LVDS input threshold is ±100 mVolt differential. Typical LVDS line impedance is 100 .

- 6 -