JAI CV-M4+, M7+ CL, CV-M7+, M4+ CL Edge Pre-select Mode, Important notes on using this mode

Models: CV-M4+ CV-M7+ M7+ CL M4+ CL

1 31
Download 31 pages 8.22 Kb
Page 17
Image 17

CV-M4+/M4+CL, CV-M7+/M7+CL

6.5. Edge Pre-select Mode

The trigger leading edge will start the exposure H synchronous or H a-synchronous (HC=0, HC=1). The exposure stops and is read out after the shutter time selected. It can be the 10 steps in normal or 1056 steps in programmable. SM=0 or SM=1. This mode will operate with full and partial scanning and with V-binning (M4+ and M4CL+ only). Partial scanning and binning in combinations is not allowed.

In this mode the Restart Continuous Trigger mode (RC=1) can be activated. (By RS-232C and CL only). The camera is then running continuously, and it can be reset and restarted by the trigger pulse.

If smearless read out (SL=1) is used, the exposure starts with a delay 133H (5.23 msec.) after the trigger. An EEN pulse will indicate the active accumulation time, and a FEN pulse indicates that the resulting video is read out.

To use this mode:

 

 

Set function:

Trigger mode “Edge Pre-select”

TR = 1

 

Shutter mode “Normal” or “Programmable”

SM=0, SM=1

 

“Shutter Speed”

SH=0 through 9

 

“Programmable exposure”

PE=0 through 1057

 

“H synchronous trigger”

HC=0, HC=1

 

“Restart Continuous Trigger”

RC=0, RC=1

 

“Smearless readout”

SL=0, SL=1

 

Polarity and other functions

 

Input:

Ext. trigger to LVDS/Camera Link or pin 10 on 12-pin connector.

Important notes on using this mode.

The duration of the trigger should be >2H to <3V. (>72.64sec to <120msec).

The minimum trigger interval should be >(exposure time + 1 frame). A new trigger must not be applied during the previous frame read out. (Before FEN is high).

Smearless readout cannot be used together with Reset Continuous Trigger.

Fig. 20. Edge Pre-select

- 16 -

Page 17
Image 17
JAI CV-M4+, M7+ CL, CV-M7+, M4+ CL operation manual Edge Pre-select Mode, Important notes on using this mode