2.Attach terminal lugs to line 1 (black), bare (green) ground, and line 2 (red) wires. Loosen (do not remove) the set screw on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs. Securely tighten set screw to torque as shown in the following Bare Wire Torque Specifications chart.
A
B
C D E
A. Terminal lug
B. Set screw
C. Line 1 (black) wire
D. Bare (green) ground wire
E. Line 2 (red) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20
Wire Awg | Torque |
8 gauge copper | 25 |
|
|
6 gauge aluminum | 35 |
|
|
3.Use ³⁄₈" nut driver to connect the bare (green) ground wire to the center terminal block post with one of the
F |
A |
E |
B
| D |
| C |
A. | D. Bare (green) ground wire |
B. Line 1 (black) | E. Line 2 (red) |
C. | F. Terminal lug |
4.Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with
5.Securely tighten hex nuts.
6.Replace terminal block access cover.
Connect Range to Downdraft System
1.Attach flexible vent (provided) to the blower motor inlet using a vent clamp.
2 | 1 |
|
A
B
A. Inlet flexible vent
B. Vent clamp
2.Check countertop height to allow range top to clear countertop. Adjusting leveling legs if necessary.
3.Remove access panel by grasping both sides, pulling upward, and lifting out.
4.Move range close to cabinet opening.
5.Plug range into grounded outlet (if using a power supply cord).
6.Plug range electrical connector into the downdraft blower motor.
A
B
A. Power supply cord (on some installations)
B. Range electrical connector to blower motor
7.Remove cardboard or hardboard from under the range. Using
2 or more people, gently move range into its final location.
19