Jenn-Air W10253462A installation instructions B A C, A E D C B, Replace access panel

Models: W10253462A

1 40
Download 40 pages 44.43 Kb
Page 20
Image 20
■Look for the anti-tip bracket securely attached to floor or wall.

8.Check that the anti-tip bracket is installed and that electrical cords are not kinked. Use a flashlight to look underneath the bottom of the range.

Look for the anti-tip bracket securely attached to floor or wall.

Slide range back so rear range foot is under anti-tip bracket.

9.Level the range.

a.) Place rack in oven.

b.) Place level on rack and check levelness of the range, first side to side; then front to back.

c.) If range is not level, pull range forward until rear leveling leg is removed from the anti-tip bracket.

d.) Use a wrench or pliers to adjust leveling legs up or down until range is level.

e.) Push range back into position.

f.) Check that rear leveling leg is engaged in anti-tip bracket. NOTE: Range must be level for satisfactory baking performance.

10.Depending on your installation, connect the flexible vent from the blower motor inlet to the range using a vent clamp.

Wall Venting

Top View

Floor Venting

Top View

B

A

C

A.Range

B.Floor venting outlet

C.Vent clamp

Side Venting (left side venting shown)

Connect flexible vent duct to range and connect vent system to blower motor outlet.

Top View

A

E

D

C

B

B

D. Vent system

A. Flexible vent duct to range

B. Vent clamp

E. Side venting outlet

C. Range

 

11. Replace access panel.

 

A

 

C

 

A. Range

 

B. Wall venting outlet

 

C. Vent clamp

 

20