Manuals
/
Jenn-Air
/
Kitchen Appliance
/
Cooktop
Jenn-Air
W10253462A installation instructions
Models:
W10253462A
1
39
40
40
Download
40 pages
44.43 Kb
33
34
35
36
37
38
39
40
<
>
Specification
Install
Exigences d’emplacement
Dimension
If connecting to a 4-wire system
Adjust Leveling Legs
Safety
Power Supply Cord
If you need Assistance or Service
Replace access panel
Page 39
Image 39
Notes
39
Page 38
Page 40
Page 39
Image 39
Page 38
Page 40
Contents
Table of Contents/Table des matières
W10253462A
INSTALLATION INSTRUCTIONS ELECTRIC DOWNDRAFT SLIDE-IN RANGES
INSTRUCTIONS D’INSTALLATION DES CUISINIÈRES ÉLECTRIQUE À ÉVACUATION
RANGE SAFETY
Your safety and the safety of others are very important
DANGER
Location Requirements
INSTALLATION REQUIREMENTS
Mobile Home - Additional Installation Requirements
Tools and Parts
A BC
Product Dimensions
Cabinet Dimensions
A F E C
Floor Venting
Venting Requirements
Venting Methods
Wall Venting
Left or Right Side Venting
Concrete Slab Installations - Exhaust Through Wall
Concrete Slab Installations Exhaust Through Window Well
Calculating Vent System Length
Electrical Connection
If connecting to a 4-wire system
Electrical Requirements - U.S.A. Only
Example vent system
for Slide-in Ranges Only
If connecting to a 3-wire system
Electrical Requirements - Canada Only
Countertop Preparation
Unpack Range
INSTALLATION INSTRUCTIONS
Adjust Leveling Legs
Install Anti-Tip Bracket
Install Downdraft System
Determine Equivalent Length of Vent System
Rear Wall Venting
6. Go to the “Electrical Connection” section
B A A B
A A B
Floor Venting
Left or Right Side Venting
A B CD
8. Position 2 wood spacers and mount them to the floor
Power Supply Cord
Direct Wire
Electrical Connection - U.S.A. Only
Style 2 Direct wire strain relief
connecting to
4-wire connection Power Supply Cord
A B C
A B C D
A B C D
3-wire connection Power Supply Cord
Direct Wire Installation Copper or Aluminum Wire
4-wire Connection Direct Wire
Wire Awg
Bare Wire Torque Specifications
3-wire connection Direct Wire
A B C D E
Connect Range to Downdraft System
Bare Wire Torque Specifications
A B C D E
Look for the anti-tip bracket securely attached to floor or wall
B A C
A E D C B
11. Replace access panel
Moving the Range
Complete Installation
If you need Assistance or Service
For power supply cord-connected ranges
Failure to do so can result in death or electrical shock
For direct-wired ranges
Electrical Shock Hazard Disconnect power before servicing
Replace all parts and panels before operating
Votre sécurité et celle des autres est très importante
SÉCURITÉ DE LA CUISINIÈRE
DANGER AVERTISSEMENT
AVERTISSEMENT
Outils nécessaires
EXIGENCES D’INSTALLATION
Exigences d’emplacement
Outils et pièces
A BC
Dimensions du placard
Dimensions du produit
A F B E
Air d’appoint
Exigences concernant l’évacuation
Installations dans les régions au climat froid
Pour obtenir des performances optimales
Évacuation par le mur
Installations sur dalle de béton - Évacuation par le mur
Installations sur dalle de béton Évacuation par un puits de fenêtre
Méthodes d’évacuation
Exemple de circuit d’évacuation
Calcul de la longueur effective du circuit d’évacuation
AVERTISSEMENT
Spécifications électriques
Préparation du plan de travail
cuisinières encastrées uniquement
AVERTISSEMENT
INSTRUCTIONS D’INSTALLATION
Déballage de la cuisinière
Réglage des pieds de nivellement
Installation de la bride antibasculement
Installation du circuit d’évacuation par le bas
Déterminer la longueur équivalente du circuit d’évacuation
Évacuation par le mur arrière
Évacuation par le plancher
1. Tracer au sol l’axe central de l’ouverture entre les placards
A A B
Évacuation par la gauche ou par la droite
A B C D
7. Voir la section “Raccordement électrique”
Raccordement de la cuisinière au circuit d’évacuation par le bas
Évacuation par le mur Vue de dessus
Évacuation par le plancher Vue de dessus
B A C
Achever l’installation
Si vous avez besoin d’assistance ou de service
E D C
AVERTISSEMENT
Déplacement de la cuisinière
Pour les cuisinières avec câblage direct
Cuisinières alimentées par cordon d’alimentation
Page
Printed in U.S.A
2009
5/09
All rights reserved