Install In-line Blower System
NOTE: The blower motor housing can be mounted using 4 holes from either the inlet side or the outlet side of the blower.
Outlet Side
AA
A
A
A. Mounting holes
Inlet Side
A
A
A. Mounting holes
1.Position the
2.Drill 4 mounting pilot holes using a ³⁄₁₆" (4.8 mm) drill bit.
3.Attach the
4.If it is removed, reinstall the blower motor assembly and secure it with the screws previously removed.
5.If it is removed, reattach the motor electrical plug to the connector on the blower motor assembly.
Complete Preparation
1.Determine and make all necessary cuts for the vent system.
IMPORTANT: When cutting or drilling into the floor, ceiling or wall, do not damage electrical wiring or other hidden utilities.
2.Determine the location where the ¹⁄₂" (1.3 cm) wiring conduit will be routed through the floor, ceiling or wall between the in- line blower and the downdraft vent.
3.Drill a 1¹⁄₄" (3.2 cm) hole at this location.
4.Locate the electrical terminal boxes in the
B
A
A. Electrical terminal box
B. Electrical knockout
5.Remove the electrical knockout from the
6.With the downdraft vent mounted, run the ¹⁄₂" (1.3 cm) wiring conduit between the
7.Run the six 18 AWG wires through the ¹⁄₂" (1.3 cm) wiring conduit and conduit connectors and into the terminal boxes on the
8.Install the conduit connectors and conduit to the
9.Connect the vent system to the downdraft vent and
11