Make Electrical Connections for In-Line Blower Motor System
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Electrical Connection Inside In-line Blower System
1.Disconnect power.
2.Connect the wires from the wiring conduit to the wires from the motor electrical plug cable inside the
7.Use UL listed wire connectors and connect the gray wires (G) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in terminal box.
Failure to do so can result in death or electrical shock.
8. Connect the green (or yellow/green) ground wire to the |
green/yellow ground wire (H) in the terminal box using UL |
listed wire connectors. |
B
A
J
A. UL listed or CSA approved ¹⁄₂" (1.3 cm) wiring conduit
B. UL listed wire connectors C. Black wires
D. White wires E. Red wires
C
D
E
F
G
H
I
F. Blue wires G. Gray wires
H. Green (or yellow/green) and green/yellow wires
I. Motor electrical plug cable
J. UL listed or CSA approved ¹⁄₂" (1.3 cm) strain relief
9. | Reinstall the |
10. | Reinstall the front cover of the |
| secure it with 10 mounting screws. |
Electrical Connection Inside Downdraft Vent Between In- line Blower System and Downdraft Vent
NOTE: Discard the
1.With the downdraft vent mounted, locate the terminal block inside the downdraft vent junction box.
2.Using a small ¹⁄₈"
3.Connect the same color wire from the
4.Tighten the terminal block screws.
A |
3.Use UL listed wire connectors and connect the black wires
(C)together.
4.Use UL listed wire connectors and connect the white wires
(D)together.
5.Use UL listed wire connectors and connect the red wires (E) together.
6.Use UL listed wire connectors and connect the blue wires (F) together.
| B | J | I | |
|
| |||
| C |
|
| |
| D |
|
| |
| E |
| H | |
| F | G | ||
|
| |||
A.Downdraft vent junction box | G. Terminal block |
| ||
B. Black wires | H. Power supply cord |
| ||
C. Gray wires | I. ½" (1.3 cm) UL listed or CSA | |||
D. Red wires | approved wiring conduit | |||
E. White wires | from | |||
J. ½" (1.3 cm) UL listed or CSA | ||||
F. Green (or yellow/green) | ||||
approved conduit connector | ||||
and green/yellow wires | ||||
|
|
|