Make sure the lathe is properly grounded.
Power is connected properly when pulling up on the
To Switch from 230V to 460V Operation
WARNING
Disconnectthe machine from the power
source!
Failure to do so may cause serious injury!
Main Motor: Change the wires according to the diagram on the inside of the motor junction box.
Transformer: Remove electrial panel on rear of the machine, headstock side, switch wire from 230V terminal to 460V terminal as outlined on the transformer.
Coolant Pump: Open access panel on the base at the tailstock end. Change wires in coolant pump junction box according to diagram on the inside of the junction box cover.
12