701379-UIM-C-0712

For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available on-line at www.upgnet.com in the Product Catalog Section.

AC 9A

Single Stage Air Conditioner – Two Stage Variable Speed Furnace

 

THERMOSTAT

THERMOSTAT

THERMOSTAT

THERMOSTAT

 

 

 

 

 

 

 

 

*DN22U00124

*PP32U70124

*DN22C00124

*DP22U70124

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

C

C

C

 

 

24 – Volt Common

24 – Volt Common

24 – Volt Common

24 – Volt Common

 

 

Y

Y

Y

Y1

 

 

First Stage Compressor

First Stage Compressor

First Stage Compressor

First Stage Compressor

 

 

R

R

R

R

 

 

24 – Volt Hot

24 – Volt Hot

 

 

24 – Volt Hot

24 – Volt Hot

 

 

(Heat XFMR)

(Heat XFMR)

 

 

 

 

 

 

G

G

G

G

 

 

Fan

Fan

Fan

Fan

 

 

W

W

W

E/W1

 

 

First Stage Heat

First Stage Heat

First Stage Heat

First Stage Heat

 

 

 

 

 

 

 

 

W2

W2

W2

W2

 

 

Second Stage Heat

Second Stage Heat

Second Stage Heat

Second Stage Heat

 

 

RC

RC

 

 

 

 

24 – Volt Hot

24 – Volt Hot

 

 

 

 

 

 

 

 

(Cool XFMR)

(Cool XFMR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y2

Y2

Y2

Y2

 

 

Second Stage

Second Stage

Second Stage

Second Stage

 

 

Compressor

Compressor

Compressor

Compressor

 

 

 

 

 

 

 

 

 

 

2

External Humidistat

 

 

 

 

 

 

 

 

(Optional)

 

 

 

 

 

 

 

 

 

 

Open on Humidity Rise

 

ID MODELS

PV(8/9)

(F/L)*(8/9)V

(G/L)*(8/9)V

TM(8/9)V

TWO STAGE

VARIABLE SPEED

FURNACE

1

TWO STAGE

VARIABLE SPEED

 

 

FURNACE CONTROL

 

C

 

24 – Volt Common

 

Y1

 

Single Stage

 

Compressor

 

R

 

24 – Volt Hot

 

G

 

Fan

 

W/W1

 

First Stage Heat

 

W2

 

Second Stage Heat

 

Y/Y2

 

Second or Full

 

Stage Compressor

 

O

 

Reversing Valve

 

X/L

 

Malfunction Light

 

DHUM

 

Dehumidification

SINGLE STAGE

AIR

CONDITIONER

C

24 – Volt Common

Y Y

CompressorCompressorContactor

Connection of the “C”

Connection of the “C”

Connection of the “C”

Connection of the “C”

terminal, 24-volt common

terminal, 24-Volt common

terminal, 24-Volt common

terminal, 24-Volt common

is optional when used with

is optional when used with

is optional when used with

is optional when used with

batteries

batteries

batteries

batteries

Thermostat Installer Setup

Thermostat Installer Setup

 

Step 1 of Thermostat User

1-System Type-must

0170-System Type-must

 

Configuration Menu must

be set to 7-2 Heat/1 Cool

be set to 9-2 Heat/1 Cool

 

be set to MS 2

Multistage Conventional

Multistage Conventional

 

 

 

Thermostat Installer Setup

 

 

 

 

15-Compressor Protection

 

 

 

 

-must be set to 5

 

 

 

 

 

2

Part Number:

 

 

 

 

S1-2HU16700124

 

 

 

 

 

 

1

Move DHUM

jumper to “YES”

if humidistat is to be used.

Part Numbers:

SAP = Legacy

265904 = 031-09169

449572

FIGURE 18: Thermostat Chart - Single Stage Air Conditioners with Two Stage Variable Speed Furnaces

Johnson Controls Unitary Products

13

Page 13
Image 13
Johnson Controls TM9V*MP installation manual AC 9A

TM9V*MP specifications

Johnson Controls has long been a leader in providing innovative comfort solutions, and their TM9V*MP series of variable speed air handlers is a testament to their commitment to efficiency and performance. These products are designed to optimize heating and cooling in both residential and commercial applications, ensuring superior indoor air quality and comfort year-round.

One of the standout features of the TM9V*MP series is its variable speed technology. Unlike traditional single-speed systems, the TM9V*MP adjusts its airflow according to real-time heating and cooling demands. This not only enhances comfort by maintaining consistent temperatures but also significantly reduces energy consumption. The variable speed motor operates quietly and efficiently, making it ideal for both living environments and workplaces.

In terms of design, the TM9V*MP is engineered for ease of installation and maintenance. It comes in a compact size that allows for flexible positioning within existing ductwork, making retrofits simpler for contractors. Additionally, the modular design allows for easy access to internal components, which facilitates hassle-free servicing and maintenance.

The unit also features a robust filtration system that works in tandem with a range of air quality technologies. This includes optional media filters that capture allergens and particulates, ensuring that the air quality within a space is not only comfortable but also healthy. The integration of advanced technologies, such as integrated Wi-Fi capabilities, provides users with the ability to monitor and adjust settings remotely via smartphones or tablets.

Moreover, the TM9V*MP series is compatible with a wide range of communication protocols, enabling seamless connectivity with smart home systems. This means that users can create customized comfort profiles and take advantage of energy-saving features automatically.

Durability is another key characteristic of the TM9V*MP series. Built with high-quality materials and subjected to rigorous testing, these air handlers are designed to endure even the most demanding conditions while providing reliable performance over time.

In summary, Johnson Controls' TM9V*MP series offers an array of features that cater to modern comfort demands. With its variable speed technology, user-friendly design, air quality enhancements, and strong connectivity options, it stands out as a prime choice for both residential and commercial HVAC applications, setting a high standard for efficiency and indoor comfort.