Johnson Controls TM9V*MP Section Iii Filters, UIM-C-0712, Filter Installation, Dimensions, A in

Models: TM9V*MP

1 40
Download 40 pages 32.39 Kb
Page 9
Image 9
FIGURE 13: Dimensions

701379-UIM-C-0712

LEFT SIDE

Combustion Air Inlet

Condensate Drain

Gas Pipe

(Downflow)

Entry

Vent Outlet

Electrical

 

Entry

 

Condensate

 

Drain

 

Thermostat

 

Wiring

28.5”

 

29.5”

 

(For Cladded door add appoximately an additional .75”)

FRONT

A

 

 

RIGHT SIDE

 

 

 

Combustion Air Inlet

 

 

Gas Pipe

Condensate Drain

 

 

Entry

(Downflow)

 

 

Electrical

 

 

 

Entry

Vent Outlet

 

33

Condensate

23”

 

 

Drain

 

 

 

 

 

Thermostat

Optional Return Air

 

 

Wiring

14”

 

Cutout (Either side)

 

 

 

 

 

 

 

 

1”

 

 

1.5”

 

.56”

23.8”

3”

 

 

 

Vent

 

 

Outlet

B

Combustion

B

 

Air Inlet

C

 

 

.56”

.56”

24.25”

20”

 

SUPPLY END

 

 

 

 

 

 

RETURN END

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 13: Dimensions

 

 

 

 

 

 

 

 

Table 3: Cabinet and Duct Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BTUH (kW)

Nominal

 

Cabinet

 

Cabinet Dimensions (Inches)

 

Approximate

 

 

 

Operating Weights

Input

CFM (m3/min)

 

Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A (in)

A (cm)

B (in)

B (cm)

C (in)

C (cm)

Lbs (kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40 (11.7)

1000 (28.3)

 

A

14 1/2

36.8

13 3/8

34.0

11 3/4

29.8

113 (51.2)

60 (17.6)

1200 (34.0)

 

B

17 1/2

44.4

16 3/8

41.6

13 1/4

33.7

122 (55.3)

80 (23.4)

1200 (34.0)

 

B

17 1/2

44.4

16 3/8

41.6

14 3/4

37.5

126 (57.1)

80 (23.4)

1600 (45.3)

 

C

21

53.3

19 7/8

50.5

16 1/2

41.9

136 (61.7)

100 (29.3)

1600 (45.3)

 

C

21

53.3

19 7/8

50.5

18 1/4

46.4

142 (64.4)

100 (29.3)

2000 (56.6)

 

C

21

53.3

19 7/8

50.5

18 1/4

46.4

145 (65.8)

120 (35.1)

2000 (56.6)

 

D

24 1/2

62.2

23 3/8

59.4

21 3/4

55.2

156 (70.7)

SECTION III: FILTERS

FILTER INSTALLATION

All applications require the use of a field installed filter. All filters and mounting provision must be field supplied.

Filters must be installed external to the furnace cabinet. DO NOT

attempt to install filters inside the furnace.

NOTICE

Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer’s recommendation and a transition is used to allow use on a 20x25 filter.

Table 4: Recommended Filter Sizes (High Velocity 600 FPM)

CFM

Cabinet

Side

Bottom

(m³/min)

Size

(in)

(in)

1000 (28.3)

A

16 x 25

14 x 25

 

 

 

 

1200 (34.0)

B

16 x 25

16 x 25

 

 

 

 

1600 (45.3)

C

16 x 25

20 x 25

 

 

 

 

2000 (56.6)

C

(2) 16 x 25

20 x 25

 

 

 

 

2000 (56.6)

D

(2) 16 x 25

22 x 25

 

 

 

 

1.Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters.

2.Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one side return with a transition to allow use of a 20x25 filter.

Johnson Controls Unitary Products

9

Page 9
Image 9
Johnson Controls TM9V*MP Section Iii Filters, UIM-C-0712, Filter Installation, Johnson Controls Unitary Products, BTUH kW