Johnson Controls TM9V*MP UIM-C-0712, High / Low Speed Cooling And Heat Pump Cfm, 040A10, 060B12

Models: TM9V*MP

1 40
Download 40 pages 32.39 Kb
Page 34
Image 34
HIGH / LOW SPEED COOLING AND HEAT PUMP CFM

701379-UIM-C-0712

Table 18: Air Flow Data

 

 

HIGH / LOW SPEED COOLING AND HEAT PUMP CFM

 

 

 

040A10

 

060B12

 

080B12

Jumper Settings

High

Low

High

Low

High

Low

COOL Tap

ADJ Tap*

1080

750

1343

865

1320

882

A

B

960

680

1116

727

1093

755

B

B

980

690

1235

791

1203

810

A

A

870

620

1026

661

1001

693

B

A

890

620

1079

709

1080

730

A

C

770

550

889

590

880

641

C

B

790

560

900

599

910

642

B

C

650

480

787

531

803

585

D

B

700

500

814

542

836

597

C

A

590

440

712

490

738

557

D

A

640

450

725

499

749

561

C

C

540

400

641

456

682

529

D

C

 

080C16

 

100C16

 

100C20

Jumper Settings

High

Low

High

Low

High

Low

COOL Tap

ADJ Tap*

1787

1171

1818

1192

2019

1290

A

B

1503

987

1545

1030

1790

1174

B

B

1620

1053

1661

1083

1818

1195

A

A

1405

914

1427

936

1630

1068

B

A

1462

964

1497

991

1649

1082

A

C

1217

785

1234

819

1269

848

C

B

1245

818

1265

832

1432

956

B

C

940

608

977

648

1078

704

D

B

1091

702

1116

728

1169

770

C

A

852

551

884

572

986

638

D

A

983

626

1019

666

1062

685

C

C

764

544

791

519

866

576

D

C

 

 

 

 

 

120D20

Jumper Settings

 

 

 

 

High

Low

COOL Tap

ADJ Tap*

 

 

 

 

2006

1397

A

B

 

 

 

 

1687

1131

B

B

 

 

 

 

1845

1282

A

A

 

 

 

 

1552

1050

B

A

 

 

 

 

1694

1157

A

C

 

 

 

 

1502

1011

C

B

 

 

 

 

1400

944

B

C

 

 

 

 

1365

922

D

B

 

 

 

 

1364

931

C

A

 

 

 

 

1232

808

D

A

 

 

 

 

1225

808

C

C

 

 

 

 

1117

718

D

C

 

 

 

HIGH / LOW HEAT CFM

 

 

 

 

040A10

 

060B12

 

80B12

Jumper Settings

High

Low

High

Low

High

Low

HEAT Tap

ADJ Tap*

960

670

1364

843

1433

945

A

Any

840

590

1253

745

1320

887

B

Any

740

520

1102

660

1223

840

C

Any

640

450

1014

607

1134

768

D

Any

 

80C16

 

100C16

 

100C20

Jumper Settings

High

Low

High

Low

High

Low

HEAT Tap

ADJ Tap*

1684

1095

1803

1182

2194

1417

A

Any

1542

1011

1686

1084

1999

1290

B

Any

1426

927

1530

1016

1799

1182

C

Any

1289

832

1427

936

1614

1062

D

Any

 

 

 

 

 

120D20

Jumper Settings

 

 

 

 

High

Low

HEAT Tap

ADJ Tap*

 

 

 

 

1937

1323

A

Any

 

 

 

 

1757

1199

B

Any

 

 

 

 

1594

1062

C

Any

 

 

 

 

1429

957

D

Any

All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6” w.c. static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0” w.c. external static pressure is not recommended.

NOTE: At some settings, LOW COOL and/or LOW HEAT airflow may be lower that what is required to operate an airflow switch on certain models of electronic air cleaners. Consult the instructions for the electronic air cleaner for further details.

* The ADJ “D” tap should not be used.

34

Johnson Controls Unitary Products

Page 34
Image 34
Johnson Controls TM9V*MP UIM-C-0712, High / Low Speed Cooling And Heat Pump Cfm, 040A10, 060B12, 080B12, Jumper Settings