Vent Terminal Clearances
Figure 10. Vent Terminal Clearances - National Fuel Gas Code.
A = Clearance above grade, veranda, porch , deck, or balcony : *12 inches (30 cm) minimum.
B = Clearance to window or door that may be opened: 9 inches (23 cm) minimum. 12 inches is recom- mended to help prevent condensation.
C = Recommended clearance to permanently closed
window: mimimum 12 inches (30 cm) to help prevent condensation on the window.
D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the centerline of the terminal: 18 inches (46 cm) minimum.
E = Clearance to unventilated soffit: 12 inches (46 cm) minimum.
F = Clearance to outside corner: 9 inches (23 cm) min.
Jøtul N.A. strongly recommends 12 inches (30 cm), particularly where windy conditions are prevalent.
*As specified in CGA B149 Installation Codes. Note: Local Codes and Regulations may require different clearances.
**A vent shall not terminate directly above a sidewalk or driveway which is located between two single family dwellings
and serves both dwellings.*
1Only permitted if veranda, porch, deck, or balcony, is fully open on a minimum of two sides beneath the floor.*
G = Clearance to inside corner: 6 inches (16 cm) min.
Jøtul N.A. strongly recommends 12 inches (30 cm), particu- larly where windy conditions are prevalent.
H = *Not to be installed above a meter/regulator assembly within 3 feet (90 cm) horizontally from the
I = Clearance to service regulator vent outlet: 6 feet (1.8 m) minimum.
J = Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance:
*12 inches (30 cm) minimum.
K = Clearance to a mechanical air supply inlet: *6 feet (1.8 m) minimum.
L = ** Clearance above paved sidewalk or a paved drive- way located on public property: *7 feet (2.1 m) min.
M = Clearance under veranda, porch, deck, or balcony:
*12 inches (30 cm) minimum. 1
| 21/2” |
12 ” | 64mm |
3053”
mm 76mm
Figure 11.Vent Terminal / Overhang Clearances
11