Jotul GF3 DVII manual Optional Wall Thermostat or Remote Control

Models: GF3 DVII

1 28
Download 28 pages 45.42 Kb
Page 20
Image 20
Optional Wall Thermostat or Remote Control

Snapstat

(attached to

blower bracket)

BLOWER

HI/LO

SWITCH

Plug

Wire Harness

Figure 22. Attaching the blower wire harness.

CAUTION:

LABEL ALL WIRES PRIOR TO

DISCONNECTION WHEN SERVICING THE CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. ALWAYS VERIFY PROPER OPERATION AFTER SERVICING THE APPLIANCE.

Optional Wall Thermostat or Remote Control

When installing a wall mounted thermostat to the Allagash it must be 750 millivolt DC two-wire circuit thermostat. The thermostat should be placed in the same room as the heater, typically 5’ off the floor. Avoid drafty areas or any area that may effect the

THERMOPILE

TH Remote Control

TP Manual background

TH

TP

VALVE

TERMINAL

BLOCK

ROCKER

SWITCH

ON

OFF

STAT

OPTIONAL

THERMOSTAT

or

REMOTE

CONTROL

accuracy of the thermostat.

The thermostat should be connected to the Allagash using a minimum of 16 gauge wire with a maximum length of 35 feet of wire.

Connect the two thermostat wire leads to the two lower terminals on the terminal block located directly above the ignitor button. Do not overtighten the connections. IT IS NOT NECESSARY TO DISCONNECT ANY OTHER WIRES. See Figure 23.

For the thermostat to work the On/Off/T-Stat switch on the back of the stove must be in the T-stat position, and the pilot light must be running, for it is the power source for the thermostat.

At the thermostat the two wires should be connected to the two connections screws on the thermostat base plate per the manufacturer’s instructions.

Remote Control

The remote receiver should be wired to the terminal block the same as the thermostat. See the instruc- tions above.

Figure 23. Wiring Diagram / Remote or Thermostat