28”
711 mm
22 3/4”
578 mm
Top Exit
27 3/4”
705 mm
Rear Exit
Centerline
243/4” 629 mm
13 1/4”
337 mm
Specifications
The Jøtul GF3 DVII Allagash is a Direct Vent wall furnace and is designed as a sealed combustion, air circulating gas appliance for residential applications. The following vent components are approved for use with the Jøtul GF3 DVII, vented directly to the outside of the house:
•Simpson
•Security Direct Vent 6/4 vent pipe
•Amerivent 6/4 vent pipe.
The Jøtul GF3 DVII Allagash gas stove is designed to operate on NATURAL GAS or PROPANE only. It manufactured and shipped prepared to burn Natural Gas. For safe and efficient operation the stove is equipped with a millivolt gas control valve with a piezo ignitor. Electrical power is only required when operat- ing the OPTIONAL forced air blower.
Input Rates
Natural Gas
26,000 BTU/hr. maximum input
20,000 BTU/hr. minimum input
Propane
26,000 BTU/hr. maximum input
20,000 BTU/hr. minimum input
Minimum Inlet Pressure:
Natural Gas: | 5.0 WC | (1.25 kPa) |
Propane: | 11.0 WC | (2.75 kPa) |
Manifold Pressure: MIN | MAX | |
Natural Gas: | 2.0 WC (.85 kPa) | 3.5 WC (.85 kPa) |
Propane: | 6.4 WC (1.60 kPa) | 10.0 WC (2.50 kPa) |
Steady State Efficiency: 82%
A.F.U.E.: 73%
Piezo Ignitor / Standing Pilot
2