Specifications

The Jøtul GF3 DVII Allagash is a Direct Vent wall furnace and is designed as a sealed combustion, air circulating gas appliance for residential applications. The following vent components are approved for use with the Jøtul GF3 DVII, vented directly to the outside of the house:

Simpson Dura-Vent 6 5/8" X 4" GS pipe

Security Direct Vent 6/4 vent pipe

Amerivent 6/4 vent pipe.

The Jøtul GF3 DVII Allagash gas stove is designed to operate on NATURAL GAS or PROPANE only. It manufactured and shipped prepared to burn Natural Gas. For safe and efficient operation the stove is equipped with a millivolt gas control valve with a piezo ignitor. Electrical power is only required when operat- ing the OPTIONAL forced air blower.

Input Rates

Natural Gas

26,000 BTU/hr. maximum input

20,000 BTU/hr. minimum input

Propane

26,000 BTU/hr. maximum input

20,000 BTU/hr. minimum input

Minimum Inlet Pressure:

Natural Gas:

5.0 WC

(1.25 kPa)

Propane:

11.0 WC

(2.75 kPa)

Manifold Pressure: MIN

MAX

Natural Gas:

2.0 WC (.85 kPa)

3.5 WC (.85 kPa)

Propane:

6.4 WC (1.60 kPa)

10.0 WC (2.50 kPa)

Steady State Efficiency: 82%

A.F.U.E.: 73%

Piezo Ignitor / Standing Pilot