Chapter 3Operation
HJT Model 100 User's Guide 3-19
#MAIN MENU Description
#Sub-Menu Description
6. CONVERGENCE Displays the following convergence parameters:
1R
EGISTRATION XY adjustment for red, green and blue.
2T
HRESHOLD R, G, and B adjustment for varying the brightness of the dark
areas of the screen.
3S
ENSITIVITY R, G, and B adjustment for varying the brightness of the bright
areas of the screen.
4T
HRESHOLD
OFFSET
R, G, and B adjustment for offsetting the brightness of t he dar k
areas of the screen.
5S
ENSITIVITY
OFFSET
R, G, and B adjustment for offsetting the brightness of t he br ight
areas of the screen.
6B
LACK LEVEL G2 adjustment for red, green, and blue.
7R
ESET Menu for Registration, Threshold, and Sensitivity. Resets
Registration to 128, Threshold to 128, and Sensitivity to 128.
It is also color-selectable.
7. SYSTEM Displays the SYSTEM MENU and its six (6) submenus as shown below:
1T
EST PATTERN Provides selection of nine different test patterns as described in
Chapter 3.
2P
ROJECTION LENS Value adjustment for zoom and focus.
3P
REFERENCES Allows operator to select menus with or without numbers,
SHUTTERS ON HIDE, or FOCUS ENABLE:
1N
UMBERED MENUS Toggle ON OR OFF. The default is ON.
2D
ISPLAY LOGO ON OR OFF. The default is ON and
displays the HJT Logoat startup.
3S
HUTTERS ON HIDE Covers the R, G, or B ILA® assembly to
prevent the ILA® window from
appearing on the screen.
4F
OCUS ENABLE When box is checked focusing is allowed.
When box is unchecked focusing is
disabled to prevent accidental focusing.
Default is ON.
continued