Chapter 3Operation
HJT Model 100 User's Guide 3-23
3.13.2. Communications Protocol
Select SETTINGS using the menu bar, then select COMMUNICATIONS.
Set the following communications parameters and modes.
Table 3.0-9 Communication Protocol
Modes Parameters
Baud Rate 9600
Data Bits 8
Parity None
Parity Check No
Connector Com1this is PC configuration dependent
Stop Bits 1
Flow Control XON/XOFF
Carrier Detect No
Select FILE from the menu bar and select NEW. Under FILE NAME enter VT-100.TRM.
This will allow the user to select the file VT-100.TRM with the parameters listed in
Table 3.0-9 saved for future use.
Table 3.0-10 VT-100 Terminal and Remote Command Equivalents
Action Keyboard
Input
Standard
Remote
Keys
Technician
Remote
Keys Decimal Hex
Power OFF (All) CTRL + F 6 6
Power ON (All) CTRL + U 21 15
Power ON/OFF CTRL -P Power Power 16 10
Power ON/OFF
(Electronics only) CTRL + E 5 5
Power ON/OFF Lamp CTRL + L 12 0C
Left Arrow Left Arrow Left Arrow Left Arrow 27 91 68
1B 5B 44
Right Arrow Right Arrow Right Arrow Right Ar row 27 91 67
1B 5B 43
Up Arrow Up Arrow Up Arrow Up Arrow 27 91 65
1B 5B 41
Down Arrow Down Arrow Down Arrow Down Arrow 27 91 66
1B 5B 42
Back out of menu ESC ESCAPE ESCAPE 27 1B
Blanking B Blank 66 42
Bow, H & V U Bow 85 55
Brightness IBright7349
Center, H & V (RGB) P Center 80 50
Change channel Number
+ ENTER
Channel #
+ ENTER
Channel #
+ ENTER
48-57 30-39 + 0D
Color Y8959
Contrast (RGB) C Cont 67 43
Edge, H & V (RGB) E EdgeLin 69 45
Enter ENTER ENTER ENTER 13 0D
Escape Esc ESCAPE ESCAPE 27 1B