JVC CB100 manual Terminal Preference Selections, Terminal Preferences

Models: CB100

1 128
Download 128 pages 32.1 Kb
Page 98
Image 98

Chapter 4—Setup Adjustments

Table 4.0-9 Terminal Preference Selections

Terminal Preferences

Terminal Modes

=

Sound

CR#CR/LF

=

OFF

 

 

 

Columns

=

80

 

 

 

Cursor

=

Block and Blink

 

 

 

Terminal Font

=

Fixedsys 15

 

 

 

Translation

=

none

 

 

 

Show Scroll Bars

=

ON

 

 

 

Buffer Lines

=

100

Use Function Arrow

and Control keys for Windows = OFF

Select OK.

7.Under Settings select Text Transfer = Standard Flow Control. Select OK.

8.Under Settings select Communications and choose.

Table 4.0-10 Terminal Preference Selections

 

 

 

Connector

= PC port being used

 

 

Baud Rate

= 9600 or 19200

 

 

 

Data Bits

=

8

 

 

 

Stop Bits

=

1

 

 

 

Parity

=

none

 

 

 

Parity Check

=

OFF

 

 

 

Carrier Detect

=

OFF

 

 

 

Flow Control

=

XON/SOFF

Depends on the System Controller Switch Block:

Pos 4 ON = 9600 Pos 4 OFF = 19200

Select OK.

9.Press CTRL + SHIFT+_ to reboot the BOOT MANAGER. The Power On LED stays Red.

NOTE: The switch block at SW1 of the System Controller Board controls the baud rate for Serial Port A for the Boot Manager and System Software. This switch is factory-set ON for switch positions 1-4.

If new software will not load correctly and it becomes necessary to check this switch, contact HJT Field Service.

10.The following should be displayed on the WINDOWS TERMINAL screen (where x.x.0 is the currently loaded Boot Manager version [e.g. 1.3.0]).

4-46

Hughes-JVC Technology Corporation

Page 98
Image 98
JVC CB100 manual Terminal Preference Selections, Terminal Preferences