External Control
About the external control
This monitor has three external control terminals.
•MAKE/TRIGGER terminal
(1)MAKE (make contact) system: Controls the monitor by
(2)TRIGGER (trigger) system: Controls the monitor by sending the pulse signal instantaneously to the corresponding pin terminal.
☞“Using the MAKE/TRIGGER system” on the right
•
•
Set the following items of “REMOTE SETTING” in
(☞ “SERIAL TYPE,” “PARALLEL TYPE” on page 16).
Control |
|
| The settings of this unit | ||
Control system | “SERIAL | “PARALLEL | |||
terminal | TYPE” | TYPE” | |||
|
| ||||
|
|
| setting | setting | |
MAKE/ | MAKE |
| — | MAKE | |
TRIGGER |
|
|
|
| |
TRIGGER |
| — | TRIGGER | ||
terminal |
|
|
|
| |
Serial | RS485*1 | — | |||
terminal | communication |
|
| ||
|
|
| |||
|
| RS232C*1 | — | ||
terminal |
|
|
| ||
|
|
|
|
*1 For a monitor connected to a personal computer etc, select the terminal the equipment is actually connected to. For other monitors, select “RS485.”
Control priority is as follows.
MAKE > TRIGGER = serial communication = buttons and menu on the monitor
•You can use external control even when “CONTROL LOCK” is set to “VOL.LOCK” or “ALL LOCK” (☞ page 17).
•When the monitor is off (on standby), external control is not available. But certain external controls (starting/terminating communication, turning on the monitor) are available through the serial communication (☞ page 21).
<MAKE/TRIGGER system>
You can control the monitor by a personal computer or dedicated controller*2.
•“Using the MAKE/TRIGGER system” on the right.
*2 The controller is not commercially available. Consult your dealer if you need it.
<Serial communication>
PC, etc. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
or | OUT | IN | OUT | IN | OUT | ||||
|
|
|
|
|
|
|
|
• For the details, see page 20.
Using the MAKE/TRIGGER system
The MAKE/TRIGGER terminal is configured as follows. You can assign a function to each pin terminal in “REMOTE SETTING” (☞ “PIN1, PIN2, PIN3, PIN4, PIN5” in “PARALLEL TYPE” on page 16).
•You cannot change the functions assigned to the pin terminals from 6th to 8th.
| Pin No. | Pin name |
| 1 | PIN1 |
| 2 | PIN2 |
| 3 | PIN3 |
| 4 | PIN4 |
| 5 | PIN5 |
This is a female terminal. | 6 | TALLY*1 |
| 7 | ENABLE*2 |
| 8 | GND |
*1 The 6th pin terminal controls turning on or off the tally lamp (available to control even when the 7th pin terminal is invalid).
*2 The 7th pin terminal makes the external control valid/invalid. Make sure to control the terminal by the MAKE system.
To assign the functions to the pin terminals
For the operation procedure, see page 12.
1Select “REMOTE SETTING” on the
2Set “PARALLEL TYPE” to “SET.”
3Select a pin name (“PIN1” – “PIN5”) for which you want to assign a function, then select the function you want to assign.
For the selectable functions, see the table on page 19.
Operation of the external control
1Set “PARALLEL TYPE” of “REMOTE SETTING” to “MAKE” or “TRIGGER” in the
2
3When the “MAKE” system is selected: Operate each function by
When the “TRIGGER” system is selected: Operate each function by pulse control, that is
•When changing the input with MAKE system, only one pin terminal must be
•When selecting the “TRIGGER” system, you can operate only one function at a time. Operate the functions one by one.
18