23
ENGLISH
<Basic command list>
No. Commands Functions Data
1!***1B C N 1 Cr Starts communication (connection) No data
2!***1B C N 0 Cr Terminates communication (termination) No data
3!***1BIDSETxx*
2Cr Assigns the control ID 01 – 99
4!***1B I D R E T Cr Initializes the control ID No data
5!***1BIDDSPxx*
2Cr Displays/hides the ID 00: Hide, 01: Display
6!***1BIDCHKxx*
2Cr Flashes/hides the selected ID No. of the monitor 00: Hide, 01: Display
7!***1B M E N U Cr Displays the MAIN MENU/Quits the menu operation No data
8!***1BUPCr Moves the cursor upward ( ) No data
9!***1BDOWNCr Moves the cursor downward ( ) No data
10 !***1B A D J R Cr Makes setting/adjustment ( ) No data
11 !***1B A D J L Cr Makes setting/adjustment ( ) No data
12 !***1B S E T U P Cr Displays the SET-UP MENU No data
13 !***1B P W 1 Cr Turns on the monitor No data
14 !***1B P W 0 Cr Turns off the monitor (on standby) No data
15 !***1B I N A Cr Selects “SDI 1” input No data
16 !***1B I N B Cr Selects “SDI 2” input No data
17 !***1B I N C Cr Selects “DVI” input No data
18 !***1B I N D Cr Selects “COMPO./RGB” input No data
19 !***1B I N E Cr Selects “VIDEO 1” input No data
20 !***1B I N F Cr Selects “VIDEO 2” input No data
21 !***1B D I S P Cr Displays the status*3No data
22 !***1BAMUTExx*
2Cr Turns muting on/off 00: Off, 01: On
23 !***1BASPxx*
2Cr Changes the aspect ratio 00: 4:3, 01: 16:9
• “Cr” is 0Dh.
• The commands for starting communication (connection) (No. 1), terminating communication (termination) (No. 2), and turning on the monitor (No. 13) can be used while the monitor is off (on standby).
*1 Enter the monitor’s ID for “ **. The initial setting of the monitor’s ID is “00.” When connecting several monitors, “00” is a command for controlling all monitors at once.
*2 Enter the appropriate data to “xx.”
*3 Displays the information shown when the INPUT SELECT button currently lit is pressed ( “On the Status Display” on page 7).
DT-V24G1_20L3G_EN.indd 23DT-V24G1_20L3G_EN.indd 23 10.1.15 3:22:27 PM10.1.15 3:22:27 PM