“EXPOSURE” Screen

Settings in bold are factory settings

 

Item

 

 

 

Function/Variable Values

“IRIS MODE”

Switch according to the lens in use.

 

 

“AUTO”

: When using auto iris lens.

 

 

“MANUAL”

: When using manual iris lens.

 

“MANUAL

For setting the iris level when “IRIS MODE” is set to “MANUAL”. (Set the iris mode

 

LEVEL”

switch on the lens side to “AUTO”.)

 

 

Increase value

: Opens the iris.

 

 

Decrease value

: Closes iris.

 

 

{Variable Values : 0 - 128 - 255}

 

 

Note

 

 

 

 

 

 

 

 

 

 

 

 

When “IRIS MODE” is set to “AUTO”, “MANUAL LEVEL” item selection will be

 

 

disabled. (Displayed as “- - - - - -”)

 

 

 

 

 

 

 

“GAIN”

For switching the electric sensitivity mode.

 

 

“STEP”

: Gain boost level can be altered using the “LEVEL” item.

 

 

“V. GAIN”

: Gain boost level can be fine-tuned using the ”LEVEL“ item.

 

 

“ALC”

: Alters gain boost level automatically according to the

 

 

 

 

 

brightness.

 

 

 

 

 

Set the maximum value at the “ALC LIMIT” item. Page 35

 

“LEVEL”

Gain boost level can be altered when gain boost mode is set as “STEP” or “V.

 

 

GAIN”.

 

 

 

 

 

{Variable “STEP” Values: –3, 0, +3, +6, +9, +12, +15, +18dB, LOLUX}

 

 

{Variable “V. GAIN” Values: –3 - 0 - 18dB 0.2dB Step}

 

 

Note

 

 

 

 

 

 

 

 

 

 

 

 

When “GAIN” is set to “ALC”, “LEVEL” item selection will be disabled.

 

 

(Displayed as “- - - - - -”)

 

 

 

 

“SHUTTER”

For switching the shutter mode.

 

 

“STEP”

: Shutter speed can be altered using the “LEVEL” item.

 

 

“V. SCAN”

: Align scan speed of monitor to eliminate horizontal lines that

 

 

 

 

 

appear when shooting the computer monitor. Shutter can be

 

 

 

 

 

fine-tuned using the “LEVEL” item.

 

 

 

 

 

Page 26 ‘Shooting the Computer Monitor’

 

 

 

 

 

 

 

 

English

E-33

Page 33
Image 33
JVC KY-F550 instruction manual Exposure Screen, Settings in bold are factory settings, Auto, Step