Signals that can be input are 480i/480p, 576i/576p and 720p/1080i, 50 Hz/60 Hz signals. For passing through when signals with scan rates as high as though output from computers have been input. This unit monitors the DVI input and output statuses at all times and displays the corresponding information on the LCD.
ADVIBUpon input of compatible signals
ANO INPUTBWhen there is no input signal
AVERIFYINGWhen there is an interruption in the DVI connection with the projector
ADVIWhen signals with scan rates as high as though output from computers are detected and then output without conversion
ARATE NOT SUPPORTEDBWhen signals not supported by this unit are detected while analog RGB or YPrPb output is selected
●It may take a while to display the screen upon input of a HDCP signal.
●In the Setup menu, set the DVI input level and type of sync signal correctly. (A Page 23)
H[IR LED] TerminalCannot be used with this processor.
I[SCREEN] TerminalFor controlling the SCREEN
●Please read the APrecautions for using the screen terminalB on Page 3 before use.
This is the DVI output terminal.
Use the DVI cable supplied with this unit to connect with the projector.
●It may take a while to project the images upon input of a HDCP signal to this unit.
●Set ASET: ACTIVE OUTPUTB of the Setup menu to AANALOG RGB+DVIB or ADVIB. (A Page 22)
Cannot be used with this processor.
This is compliant with the
●Set the ASET: RS232 ECHOB and ASET: BAUD RATEB items in the Setup menu. (A Page 24)
MExhaust FanExpels warm air to keep the system cool.
Do not block the exhaust fan. This may cause the unit to malfunction.
NAC Power Input TerminalThis is the AC power input terminal. Connect the supplied cord to this terminal.
ENGLISH
11