RS-232C External Control Description
Control of this unit is possible via a computer by connecting the computer to this unit with an
When sending a control command to this unit, insert a comma after the DVP header (without spacing), followed by specifying the command. The “#” shown in each command code represents a parameter (numerical value).
Example:To turn on the power of this unit
dvp, on [e Enter]([e Enter] denotes carriage return)
●Upon sending the command to turn on the unit, do not send the next command until this unit has started up (end of initialization).
It is possible to send multiple commands at the same time. To do so, specify the commands before the carriage return and delimit each function command using a comma.
Example : dvp, on, x, a2,srn4 [e Enter]
(Control command = header, power on, YCrCb (component) input, 16:9, 1280 720 scan rate [carriage return])
Control this unit from a computer using the standard Windows Hyper Terminal software. Set the computer as follows and connect using a standard
Communication speed : 19200 bps
Data bit | : 8 bit |
Parity | : Nil |
Stop bit | : 1 bit |
Flow Control | : Nil |