MENU OPERATION

SYSTEM RESET MENU

This menu resets the values set by the user to the initial values.

FULL AUTO

F1

SHUTTER

F3

MENU/SHUTTER

GAIN

P

 

 

 

 

 

STEP

 

 

 

 

 

 

 

STR

1/1000

ALC

 

 

HIGH

 

 

 

SHUTTER

VARIABLE

MID

 

CMP

+9dB

LUX

 

BARS

MENU

PUSH-ON

PUSH-ON

R

F2

 

F4

 

LOW

 

 

GAIN

 

 

 

 

 

M

 

 

 

 

DOWN UP

DOWN UP

 

 

 

 

 

 

 

Control knob

 

LCD display

MENU button

 

 

1.

 

6: LCD MODE

 

 

 

 

7: SYSTEM RESET

 

 

 

 

 

2.7A: SYSTEM RESET

 

 

 

 

CANCEL

3.

 

 

 

 

7A: SYSTEM RESET

 

 

 

 

 

CANCEL

4.

 

 

 

 

 

 

 

7A: SYSTEM RESET

 

 

 

 

 

OK

5.

 

 

 

 

 

 

 

 

 

STR

OFF

ALC

 

 

CMP

0dB

LUX

 

 

 

 

 

1. Press and hold the MENU button (approx. 1 second) until the LCD display shows the menu display.Then turn the con- trol knob to move the cursor () to "7: SYSTEM RESET".

2. Press the control knob to display "7A: SYSTEM RESET".

3. Press the control knob to move the cursor () to "CAN- CEL". If you do not want to reset the values you have set, press the control knob now.

4. If you want to reset the values, turn the control knob to move the cursor () to "OK".

5. Press the control knob to reset the values you have set to the initial values and return to the normal display.

Initial values

The values you've set in the menu items will be reset to the initial values shown on pages 21 to 27.

Other status settings are reset as shown below.

 

Status Setting

Initial Values

 

 

Status Setting

Initial Values

 

 

 

 

 

 

 

 

IRIS button

MANUAL

 

GAIN

STEP switch

Switch position

 

 

 

 

 

 

 

 

W.BAL switch

Switch position

 

 

V.GAIN LEVEL

0.1 dB

 

 

 

 

 

 

 

 

 

PAINT button

OFF

 

SHUTTER

SHUTTER

OFF

 

 

 

 

 

 

 

 

 

A

Bch

 

V.SCAN LEVEL

Approx. 1/100

 

 

 

 

 

 

Central value of the control

 

 

 

 

 

 

 

FULL AUTO

OFF

WHITE

WHITE PAINT

 

Rch

 

B

Bch

 

BARS

OFF

 

 

 

 

 

Central value of the control

 

 

 

 

 

 

 

F1 to F4 buttons

Initial value, OFF

 

 

 

Rch

 

 

MANUAL PAINT

Bch

 

LOLUX

OFF

 

Central value of the control

 

 

 

 

 

 

 

 

 

 

 

 

Rch

 

ALC+EEI

OFF

27