JVC TK-C215V12 manual When mounting the camera directly to the ceiling or on the wall,  Setup

Models: TK-C215V4

1 32
Download 32 pages 45.98 Kb
Page 20
Image 20
When mounting the camera directly to the ceiling or on the wall

Installation and connection

6. Loosen the pan fastening screw.

Mounting the Camera (continued)

When mounting the camera directly to the ceiling or on the wall

When mounting to a wall, replace areas indicated as “ceiling” in the procedures by “wall”.

CAUTION:

Moving the lens unit without loosening the pan fastening screw may damage the lens unit.

7.Set the switches for video images.

(TK-C215V4Apg. 10) (TK-C215V12Apg. 12)

Setup

1.Open a hole in the ceiling. (R 30 mm, 1 1/8 inches)

Make use of the template supplied to open a hole.

2.Draw the fall prevention wire mounted to the ceiling slab and the cable out from the ceiling in advance.

CAUTION:

Select a suitable fall prevention wire based on length, strength, location, material (insulation property), etc.

Use a ring on the fall prevention wire for mounting to the camera unit with an internal diameter of at least R 3.1 mm or and not larger than R 5.5 mm, and an external diameter that is not larger than R 9 mm.

3.Remove the dome cover.

As illustrated in the diagram, hold the dome ring such that the position mark comes between the thumb and index finger. Turn the ring in the counterclockwise direction to remove.

3.

Dome Ring Manual backgroundManual backgroundManual backgroundManual backgroundManual background Position mark

4.Remove the inner dome

The inner dome is secured with claws

(3 locations). Hold the inner dome and remove it from the claws.

5.Remove the outer case.

A Loosen the camera fastening screw with a screwdriver.

B To remove, turn the camera unit in the counterclockwise direction.

C Dismantle the fall prevention wire.

Inner Dome

6.

4.5. Pan fastening

7.Manual background A Screw

 

Camera

Claws

Fastening

Screw

(3 locations)

 

Manual background C

B

5.

*TK-C215V4 is used in the above illustration.

Connecting

1.Align j with the shooting direction when mounting the outer case to the ceiling.

Notes on outer case mounting screws (not supplied):

Height of screw head should be less than 4 mm.

The diameter of the attachment hole of outer case is R 4.5 mm (3/16 inch).

Do not use flathead screws.

When using an impact screwdriver, do not tighten the screws fully. Tighten using your hand instead. Failure to do so may damage the outer case.

2.Hang the fall prevention wire that has been dismantled in Step 5 C of the setup procedures to the hook.

3.Attach the fall prevention wire to the camera.

(Fall prevention wire is not included)

CAUTION:

Tighten all screws securely. Otherwise the camera may come loose and fall.

20

Page 20
Image 20
JVC TK-C215V12 When mounting the camera directly to the ceiling or on the wall, Mounting the Camera continued,  Setup