Installation and connection
About Connection Cables
The maximum connection distance varies with the type of cable used. Please refer carefully to the table for each cable during connection.
*Be sure to turn off the power of devices before connecting cables.
To video Signal Cable
To DC 12 V or AC 24 V
Power Supply
To Alarm Signal Cable
Video signal cables
Connect the coaxial cables (BNC) to the video signal output connector (BNC).
Cable | Maximum extension (No cable compensator) |
|
|
200 m | |
|
|
350 m | |
|
|
450 m | |
|
|
DC 12 V or AC 24 V power supply cable
Connect the DC 12 V or the AC 24 V power supply to the DC 12 V/AC 24 V terminals on the terminal board. To prevent connection errors or a cable disconnection, we recommend the use of lug plates for the connections. The following table shows the connection distances and connection cables provided that
Conductor diameter (mm) | R 1.0 mm | R 1.6 mm | R 2.0 mm | ||
|
| (AWG18) | (AWG14) | (AWG12) | |
|
|
|
|
| |
DC12V | 50 m | 140 m | 220 m | ||
(160ft) | (450ft) | (720ft) | |||
Maximum |
| ||||
|
|
|
| ||
| 130 m | 350 m | 550 m | ||
extension | AC24V | ||||
(420ft) | (1100ft) | (1800ft) | |||
|
| ||||
|
|
|
|
| |
DC12V | 30 m | 80 m | 130 m | ||
(90ft) | (260ft) | (420ft) | |||
Maximum |
| ||||
|
|
|
| ||
| 80 m | 210 m | 340 m | ||
extension | AC24V | ||||
(260ft) | (680ft) | (1100ft) | |||
|
| ||||
|
|
|
|
|
CAUTION:
●If thin cables are used (i.e. with a high resistance), a significant voltage drop will occur when the unit is at its maximum power consumption.
Either use a thick cable to restrict the voltage drop at the camera side to below 10 %, or place the power supply near to the camera.
When the voltage is low, the protection circuit within the camera may be triggered and the power of the camera may turn off automatically.
●Do not allow input from both a DC 12 V and AC 24 V power supply at the same time.
●When using a DC 12 V power supply, ensure that the polarities of the cable are correct.
●The product shall be powered by Class 2 only.
14