JVC TK-C215V4 manual 2.,3,  TK-C215V12

Models: TK-C215V4

1 32
Download 32 pages 45.98 Kb
Page 25
Image 25
TK-C215V12

TK-C215V12

2 types of angle of view may be selected for TK-C215V12. In general, set in a way such that the home position shoots a wide range and the alarm position a narrow range.

Use the alarm input mode selection switch to set the actions when there is an alarm input. (A pg. 13)

CAUTION:

When setting images on TK-C215V12, ensure that the lens is covered using the dome cover. This camera is equipped with a high magnification lens. When adjustment is not performed through the cover, the lens may go out of focus when the cover is attached.

When adjusting the focus, ensure that the optical axis of the lens and the center of the dome cover are aligned, and that the screen is not distorted. (See illustration below)

‹Registering home position

For registering the angle of view during monitoring under normal conditions.

4.

 

H

 

 

R

B

 

 

IRIS

LEVEL

WHT.BAL.

 

RESET/[SPOT]

2.,3.

ZOOM/FOCUS FAR TELE

L

[MEMORY]

4

4

LL PHASE

 

 

 

 

 

6

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

7

 

 

 

POSITION SELECT WIDE

NEAR

 

 

 

5

 

 

1.

ALARM POSITION

 

3

 

 

2

2

 

 

 

 

 

 

 

 

1

 

 

1.Check that the [ALARM POSITION] indicator light is turned off.

Registration of home position is enabled. Press the [POSITION SELECT] button if the [ALARM POSITION] indicator light is on.

2.Adjust the angle of view. AAdjust the field angle

Move the zoom adjustment switch in the [TELE] or [WIDE] direction to adjust the field angle.

BAdjust the focus

Move the focus adjustment switch in the [NEAR] or [FAR] direction to adjust the focus.

NOTE:

When the [ZOOM/FOCUS] switch is set to either [TELE/WIDE] or [NEAR/FAR], the iris will automatically open up for about 30 seconds and focus can be easily adjusted. During this interval, the electronic shutter mode is activated and the image may flicker. However, this is not a malfunction.

3.Press the [MEMORY] button for 2 seconds or longer.

The [ALARM POSITION] indicator light blinks for 3 times (green)

4.Adjust the brightness.

This adjustment only needs to be made when required. Use this to accommodate particular

shooting conditions.

To darken image : Counterclockwise (L side)

To brighten image : Clockwise (H side)

NOTE:

For adjusting the brightness, do not conduct it within 30 seconds after pressing the [ZOOM/ FOCUS] button.

When adjusting the iris level, set the AGC switch to AOFFB. Otherwise, when the level is turned too far toward L, the AGC function activates increasing sensitivity and the picture may look uneven.



Home position registration is completed

25

Page 25
Image 25
JVC TK-C215V4 manual 2.,3,  TK-C215V12