Setting the switches
Remove the dome cover, followed by setting the video image switches.
1. Removing the dome cover
Remove the dome cover by unfastening the 3 fastening screws using the wrench supplied.
Memo:
●The dome cover and base are connected with fall prevention wire.
Wrench (Supplied)
Fall Prevention
Wire
2. Removing the inner dome
The inner dome is fastened using lugs at 3 different positions. Grasp the inner dome and remove it from the lugs.
Note:
●Before touching the camera unit, make sure to touch the metal surface of the [MONITOR] terminal to discharge any static electricity from your body. Static electricity may cause the camera to malfunction.
3. Setting the switches
Set the switches for video images. (A Pg. 12)
| Inner |
|
| Dome |
|
| 2 |
|
Lug(x 3) | 3 LL PHASE | O |
| 1 | |
| N 2 | |
| 2 | |
| 3 | 4 |
| 4 | |
| 5 | WHT. |
| 6 | |
| 7 | BAL. |
| 8 |
|
Mounting the base
Remove the camera unit from the base and mount the base to the ceiling or wall.
When mounting to a wall, follow the procedures by replacing areas indicated as [ceiling] by [wall] accordingly.
Setup
Drill mounting holes (R30 mm, 1 1/8 inch) using the template supplied when necessary.
R30 mm
(1 1/8 inch)
Coaxial Cable
Approx. 100 mm (37/8 inch)
Power Supply Wire
(AC 24 V only when heater is in use)
1. Removing the camera unit from the base
A Unfasten the 2 fastening screws from the camera unit using a screwdriver.
B Press the 2 lugs inwards to remove the camera unit from the base.
A |
B |
Lug(x 2) |
Camera |
Base |