Setting Up the Camera Using an RM-P2580

ALARM TITLE Setup

Use the ALARM TITLE screen to set the alarm titles to be displayed when an alarm signal is transmitted. Up to 10 alarm titles (ALARM TITLE 1 to 10) can be set and each title can be up to 12 characters in length.

MENU button

SET button

 

 

 

REMOTE CONTROL UNIT RM-P2580

SETUP

 

CAMERA

POSITION

 

 

 

 

POWER

 

 

 

 

MENU

SET

ALARM

AUTO

F-1

F-2

F-3

 

 

KEY LOCK

 

 

 

 

CAMERA

 

LENS

 

 

CAMERA/POSITION

PAN/TILT

buttons

 

SPEED

 

1

2

3

CAMERA

POSI-

 

 

 

 

 

 

 

TION

 

 

IRIS

 

4

5

6

1

2

 

CLOSE

OPEN

 

 

 

OPTION

OPTION

PAN/TILT

NEAR

FOCUS

FAR

7

8

9

AUTO

AUTO

 

AF

 

PAN

PATROL

lever

WIDE

ZOOM

TELECLEAR

0

ENTER

 

 

 

 

 

 

/HOME

 

 

 

 

 

 

 

ENTER button

 

 

FAR button

 

 

TELE button

 

 

WIDE button

 

 

 

 

 

 

 

 

NEAR button

 

 

 

 

 

 

 

 

– – – M E N U – – –

 

C A M . F U N C T I O N . .

 

 

C A M . T I T L E / A L A R M . .

 

C A M . V I D E O A D J U S T . .

 

C A M . A L C / E x D R . .

 

 

H O M E M O T I O N D E T E C T . .

 

A U T O P A N / P A T R O L / T R A C E . .

 

P O S I . F U N C T I O N S E T . .

 

F A C T O R Y S E T T I N G S . .

 

SETUP menu on camera

– – – C A M E R A T I T L E / A L A R M – – –

C A M . T I T L E E D I T . .

 

A R E A T I T L E

O F F

A R E A T I T L E E D I T . .

 

A L M . T I T L E

S I Z E

D O U B L E

A L M . T I T L E

C O L O U R

W H I T E

A L A R M T I T L E E D I T . .

A L A R M I N P U T . .

A L A R M O U T P U T . .

1. Select the camera. ( RM-P2580 Instruction manual)

CAMERA button Numeric key (camera number) ENTER but- ton.

The picture of the selected camera is output.

2. Display the SETUP menu on the camera.

( P. 18, steps 1 to 4 )

MENU button (3 sec.) Select “CAMERA” with the PAN/TILT lever

SET button.

The camera moves to the home position.

3. Tilt the PAN/TILT lever up or down to move the cur- sor (>) to “CAMERA TITLE/ALARM” and press the SET button.

The TITLE/ALARM screen is displayed.

4. Move the cursor (>) onto the item “ALARM TITLE EDIT” and press the SET button.

The ALARM TITLE 1 menu is displayed.

The first few characters in the character area and title input field blink to indicate that the system is ready for a title input.

5.Tilt the PAN/TILT lever to select the first character of the title from the character area.

The character being selected blinks.

The selected character is displayed in the title input field.

6.Press the TELE button.

The first character of the title is input, and the system gets ready for the input of the second character.

If the WIDE button is pressed, the blinking position in the title in- put field moves to the left. Use this facility to correct previously input characters.

TITLE/ALARM menu

Space

Blinking

Character area

 

 

 

 

 

 

 

 

 

 

 

– – – A L A R M T I T L E 1 – – –

 

 

0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K

 

 

 

 

 

L M N O P

Q

R S T U V W X Y Z a b c d e f g

 

 

h i j k l m n o p q r s t u v w x y z . , '

 

 

– : / Ä Ö Ü Â Ê Î Ô Û Ç Ñ ä ë ï ö ü â ê î ô

 

 

û á é í ó ú à è ì ò ù ç ñ ß ¡ ¿

 

 

 

 

 

 

 

 

 

 

 

W I D E

T E L E

T I T L E N O . S E L E C T

F O C U S

Title input

field

 

 

7.

8.

9.

Press the FAR button.

The next ALARM TITLE screen is displayed.

If the NEAR button is pressed, the previous ALARM TITLE screen is displayed.

Repeat steps 5 to 7 for each alarm title.

Complete the input of all the alarm titles (ALARM TITLE 1 to 10) in this way.

Press the MENU button.

The screen returns to the previous menu.

Blinking

ALARM TITLE screen

RM-P2580 units need to be configured to display Alarm Titles. Use the RM-P2580 menu settings to do this:

1.Press and hold the MENU button for 3 seconds to display the SETUP screen on the remote control unit.

2.First select the CONTROL UNIT screen, then the DATA I/O screen and finally the INPUT ASSIGNMENT screen.

3.Select “ALARM TEXT” then “EDIT 1”, the alarm title set as ALARM TITLE 1 is displayed on the monitor.

*The alarm signals are input into the DATA I/O terminals on the rear panel of the RM-P2580.

E-32

Page 32
Image 32
JVC TK-C676 manual Alarm Title Setup, Display the Setup menu on the camera, Repeat steps 5 to 7 for each alarm title

TK-C676 specifications

The JVC TK-C676 is a professional-grade CCTV camera renowned for its impressive image quality and reliable performance in various surveillance applications. As part of JVC's reputable line of security products, the TK-C676 incorporates advanced technologies that make it a popular choice among security professionals and businesses alike.

One of the standout features of the TK-C676 is its high-resolution imaging capability. With a 1/3-inch CCD sensor, this camera delivers crisp and clear images, ensuring optimal visibility even in challenging lighting conditions. The camera offers a resolution of 540 TV lines, which allows for detailed surveillance footage that can be crucial for identifying individuals or activities in monitored areas.

Another notable characteristic of the TK-C676 is its robust low-light performance. Thanks to its sense-up technology, the camera can automatically adjust its sensitivity in low-light environments, providing better image quality without the need for external lighting. This feature is particularly valuable for nighttime surveillance or in dimly lit indoor settings, enhancing the overall effectiveness of security measures.

The TK-C676 also excels in flexibility and adaptability with its mechanical IR cut filter. This technology allows for seamless switching between day and night modes, ensuring consistent image quality during both daytime and nighttime operation. This adaptability makes the camera suitable for various applications, including retail stores, parking lots, and public spaces.

Additionally, the JVC TK-C676 features a varifocal lens with a focal length of 3.5mm to 8mm, providing users with the ability to adjust the field of view based on specific surveillance needs. This versatility enables the camera to cover wide areas or focus on particular subjects, making it ideal for both indoor and outdoor placements.

In terms of durability, the TK-C676 is built to withstand harsh environmental conditions. With a sturdy housing that resists both water and dust, this camera can be installed in various locations without compromising on performance. This reliability is essential for continuous operation in demanding environments.

Overall, the JVC TK-C676 is a well-rounded CCTV camera that offers high-resolution imaging, excellent low-light performance, and adaptable features. Its combination of advanced technology, durable construction, and flexible camera options makes it a strong choice for anyone seeking a reliable surveillance solution. Whether for commercial, industrial, or residential applications, the TK-C676 proves to be a valuable asset in enhancing security measures.