For Post Duration /api/param?application.object.postrec&200 OK
Interpretation Change parameters for PrePost + ftp. These parameters are used when recftp is set as an alarm
action. Specify 30, 15, 10, 7.5, 6, 5, 3, 2, or 1 for frame rate. Maximum Pre/Post duration is 60 seconds. Setting zero
to Pre and Post duration is invalid.
Allowed users admin, operator
Getting Alarm Output Time Setting from VN-V686
Format /api/param?peripheral.output_pin.pin(Number).duration
Example /api/param?peripheral.output_pin.pin(1).duration
Example of Response peripheral.output_pin.pin(1).duration=500&200 OK
Interpretation Acquire the current alarm output duration in millisecond. Specify 1 or 2 to Number. When returned
value is 0, it means infinite output.
Allowed users admin, operator, user
Setting Alarm Output Time for VN-V686
Format /api/param?peripheral.input_pin.pin(Number).duration=data
Example /api/param?peripheral.input_pin.pin(1).duration=50
Example of response peripheral.input_pin.pin(1).duration&200 OK
Interpretation Change the alarm output duration in millisecond. Specify 1 or 2 to Number. Specify 0, or 100 to
5000 for the duration. When 0 is set, output duration becomes infinite.
Allowed users admin, operator
Getting Alarm Output Status from VN-V686
Format /api/param?peripheral.output_pin.pin(Number).status
Example of Response peripheral.output_pin.pin(1).status=make&200 OK
Interpretation Acquire the current alarm output status. Specify 1 or 2 to Number. Either make or break will be
returned.
Allowed users admin, operator, user
Changing Alarm Output of VN-V686
Format /api/param?peripheral.output_pin.pin(Number).status=data
Example /api/param?peripheral.output_pin.pin(1).status=break
Example of Response peripheral.output_pin.pin(1).status&200 OK
Interpretation Change the alarm output. Specify 1 or 2 to Number. Specify "make" or "break" to data.
When the alarm output time is zero, alarm output is changed as this API specifies. When the alarm output time is not
zero, alarm output is changed as this API specifies, then alarm output is changed again after the alarm output time.