6.17. Maintenance
The APIs below are related to maintenance. These are equivalent to the features on the Maintenance page of the
WEB setting page. Refer to the instruction manual for details on the Maintenance page.
Initialization
Format /api/param?system.status=initialize
Example of Response system.status&200 OK
Interpretation Restore all VN-V686 settings to factory defaults. Upon doing so, all transmission services that are
in progress will be terminated. Initializing takes a few minutes. Response is returned after initializing. Do not power
off during initializing.
Allowed user admin
Firmware Update
Version upgrading is not possible using API. To do so, use the Version Upgrade feature on the Maintenance page of
the WEB setting page.
Getting Status of Auto Cleaning from VN-V686
Format /api/param?camera.motion.pan.auto_cleaning.status
Example of Response camera.motion.pan.auto_cleaning.status=off&200 OK
Interpretation Acquire status of auto cleaning. "on" or "off" is returned.
Allowed users admin, operator, user
Setting Auto Cleaning for VN-V686
Format /api/param?camera.motion.pan.auto_cleaning.status=data
Example of Response camera.motion.pan.auto_cleaning.status&202
Accepted(camera.status=save)
Interpretation Change status of auto cleaning. Specify on or off. To save the change, use "camera.status=save"
API.
Allowed user admin
Getting Time of Auto Cleaning from VN-V686
Format /api/param?camera.motion.pan.auto_cleaning.time
Example of Response camera.motion.pan.auto_cleaning.time=235959&200 OK
Interpretation Acquire time of auto cleaning. Time is returned in format of hhmmss.
94