HD 4000 C / HD 6000 C
E. Maintenance
English
Interval | Procedure | Subject Assembly | Activity | By whom |
|
|
|
|
|
monthly, or | Check | Overflow valve | Dependent on the number of | Operator |
after 200 | overflow valve |
|
| |
operating |
|
| pressure reading fluctuates between |
|
hrs. |
|
| the preset value and approx. 15 bar |
|
|
|
| below the same. On closing all |
|
|
|
| handguns, the gauge will read |
|
|
|
| approx. 0 bar. In the event of |
|
|
|
| malfunction, call customer service. | Customer |
|
|
|
| service |
|
|
|
|
|
| Check | Float switch in float | For about 5 seconds press down the | Trained |
| reservoir | float of the low water protection | operator | |
| sensor |
| facility and check the fault indication | authorised |
|
|
| on the printed circuit board. If | to open |
|
|
| necessary remove any deposits. | control |
|
|
|
| cabinet |
|
|
|
|
|
| Clean | Dirt trap upstream of float | Switch OFF unit, turn OFF water, | Operator |
| strainers | reservoir, | release pressure. Disassemble and |
|
|
| Pressure controller | clean strainers. |
|
|
|
|
|
|
| Check float | Float reservoir | Water level must stand 40 mm | Operator |
| valve |
| below the overflow weir. With float |
|
|
|
| valve closed, no water may exit. For |
|
|
|
| adjustment information, refer to the |
|
|
|
| Service Manual. |
|
|
|
|
|
|
| Check | Pressure relief valve on | When functioning correctly, the | Operator |
| pressure relief | pump | motor must reach full RPM within |
|
| valve |
| 2 seconds. If required, clean the |
|
|
|
| strainer upstream of the pressure |
|
|
|
| release valve. Prior to cleaning: |
|
|
|
| Shut OFF water, set Emergency- |
|
|
|
| STOP master switch to OFF. |
|
|
|
|
|
|
| Check | System control | Close utiliser (e.g. handgun). | Operator |
| interval |
| After the after running time (approx. |
|
|
|
| 15 sec) the pump must switch off. |
|
|
|
|
|
|
| Check | Pressure switch | The pump is stationary as no water | Operator |
| automatic |
| is being drawn. Open the handgun. |
|
| switching on |
| When the pressure in the |
|
|
|
|
| |
|
|
| 25 bar, the pump must switch on. |
|
|
|
|
|
|
| Tighten hose | All hose clamps in/on the | Tighten hose clamps with torque | Operator |
| clamps | unit | wrench. |
|
|
|
| Torque: |
|
|
|
| 28 mm nominal diameter: 2 Nm |
|
|
|
| 29 mm nominal diameter: 6 Nm |
|
|
|
|
|
|
E4 |