Karcher HD 6000 C E. Maintenance, English, Interval, Procedure, Subject Assembly, Activity

Models: HD 6000 C HD 4000 C

1 33
Download 33 pages 15.52 Kb
Page 21
Image 21
Manual background

HD 4000 C / HD 6000 C

E. Maintenance

English

Interval

Procedure

Subject Assembly

Activity

By whom

 

 

 

 

 

monthly, or

Check

Overflow valve

Dependent on the number of

Operator

after 200

overflow valve

 

high-pressure handguns used, the

 

operating

 

 

pressure reading fluctuates between

 

hrs.

 

 

the preset value and approx. 15 bar

 

 

 

 

below the same. On closing all

 

 

 

 

handguns, the gauge will read

 

 

 

 

approx. 0 bar. In the event of

 

 

 

 

malfunction, call customer service.

Customer

 

 

 

 

service

 

 

 

 

 

 

Check

Float switch in float

For about 5 seconds press down the

Trained

 

low-water

reservoir

float of the low water protection

operator

 

sensor

 

facility and check the fault indication

authorised

 

 

 

on the printed circuit board. If

to open

 

 

 

necessary remove any deposits.

control

 

 

 

 

cabinet

 

 

 

 

 

 

Clean

Dirt trap upstream of float

Switch OFF unit, turn OFF water,

Operator

 

strainers

reservoir,

release pressure. Disassemble and

 

 

 

Pressure controller

clean strainers.

 

 

 

 

 

 

 

Check float

Float reservoir

Water level must stand 40 mm

Operator

 

valve

 

below the overflow weir. With float

 

 

 

 

valve closed, no water may exit. For

 

 

 

 

adjustment information, refer to the

 

 

 

 

Service Manual.

 

 

 

 

 

 

 

Check

Pressure relief valve on

When functioning correctly, the

Operator

 

pressure relief

pump

motor must reach full RPM within

 

 

valve

 

2 seconds. If required, clean the

 

 

 

 

strainer upstream of the pressure

 

 

 

 

release valve. Prior to cleaning:

 

 

 

 

Shut OFF water, set Emergency-

 

 

 

 

STOP master switch to OFF.

 

 

 

 

 

 

 

Check run-on

System control

Close utiliser (e.g. handgun).

Operator

 

interval

 

After the after running time (approx.

 

 

 

 

15 sec) the pump must switch off.

 

 

 

 

 

 

 

Check

Pressure switch

The pump is stationary as no water

Operator

 

automatic

 

is being drawn. Open the handgun.

 

 

switching on

 

When the pressure in the

 

 

 

 

high-pressure network drops below

 

 

 

 

25 bar, the pump must switch on.

 

 

 

 

 

 

 

Tighten hose

All hose clamps in/on the

Tighten hose clamps with torque

Operator

 

clamps

unit

wrench.

 

 

 

 

Torque:

 

 

 

 

28 mm nominal diameter: 2 Nm

 

 

 

 

29 mm nominal diameter: 6 Nm

 

 

 

 

 

 

5.956-648 A10369 (06/98)

E4

Page 21
Image 21
Karcher HD 6000 C, HD 4000 C E. Maintenance, English, Interval, Procedure, Subject Assembly, Activity, By whom