HD 4000 C / HD 6000 C

F. Trouble Shooting

English

Problem

Possible cause

Remedy

by whom

 

 

 

 

 

Insufficient water in

Check site water supply

Operator

 

float tank

 

 

General fault and

 

 

 

“Water supply fault”

 

 

 

LED light up on

 

 

 

printed circuit board

Temperature of the water

Reduce inlet temperature

Operator

 

inlet too high

 

 

 

 

 

 

 

Cooling water quantity too

 

 

 

low:

 

 

General fault and

Strainer in pressure reduction

Clean strainer

Operator

“HD pump

valve contaminated

 

 

temperature fault”

 

 

 

 

 

LED light up on

Mains water pressure too low

Raise pressure

Operator

printed circuit board

Cooling coil calcified,

Decalcify,

Operator

 

 

solenoid valve defective

replace solenoid valve

 

 

 

 

 

 

Oil level too low

Check oil level

Customer

 

 

 

Service

 

 

 

 

 

Oil change not made, owing

Check pump parts,

Customer

 

to which there is oil carbon

replace as necessary.

Service

 

under the piston guide shoes,

Make an oil change

 

 

piston seizing.

 

 

 

 

 

 

 

Rotation direction of

Change rotation direction

Electrician

 

precompression pump wrong

 

 

General fault and

 

 

 

“Admission pressure

 

 

 

of hot-water pump

 

 

 

too low” LED light

 

 

 

up. (Only with ABS

Pressure switch

Replace pressure switch

Customer

hot water)

precompression hot-water

 

Service

 

pump in the ABS hot water

 

 

 

defective

 

 

 

 

 

 

 

Too many utilisers

Close down some utilisers

Operator

 

simultaneously opened

 

 

General fault and

 

 

 

“Drop in system

 

 

 

pressure” LED light

 

 

 

up on the printed

Pipe burst in the

Turn off installation and

Customer

circuit board (flow

high-pressure network

repair pipeline

Service

without pressure

 

 

 

longer than

Pressure switch defective

Replace pressure switch

Customer

15 seconds)

 

 

Service

 

 

 

 

5.956-648 A10369 (06/98)

F2

Page 25
Image 25
Karcher HD 6000 C, HD 4000 C operating instructions English Problem Possible cause Remedy By whom