F. Trouble Shooting

HD 4000 C / HD 6000 C

 

Motor protection switch

Check voltage of the three

Customer

 

Q1 or Q2 has triggered

phases

Service/

Motor fault lights up

owing to overcurrent or

 

Electrician

 

drop-out of one phase

 

 

 

of power supply

 

 

 

system

 

 

 

Motor protection switch

Set in accordance with

Customer

 

falsely set

circuit diagram

Service/

 

 

 

Electrician

 

Pressure at pump

Check pressure, adjust as

Customer

 

outlet too high

necessary

Service

 

 

 

 

Available time is less than

Site high-pressure

Seal it off

Operator

6 hours

network is leaky

 

 

 

Pressure switch

Replace

Kundendienst

 

defective

 

 

 

 

 

 

System does not start up

Site power supply

switch on

Operator

when unlock button is

interrupted

 

 

pressed, no indicator light

Emergency-STOP

switch on

Operator

illuminates

master switch off

 

 

 

 

 

 

Motor protection switch

check

Customer

 

for control system and

 

Service /

 

precompression pump

 

Electrician

 

has been triggered

 

 

 

Control-circuit fuse on

replace, check cause

Customer

 

transformer defective

 

Service /

 

 

 

Electrician

 

Printed circuit board

replace, check

Customer

 

defective, green LED

 

Service

 

does not blink

 

 

 

EPROM loose

install again, check cause

Customer

 

 

 

Service /

 

 

 

Electrician

 

 

 

 

F3