TROUBLE SHOOTING THE GAS CONTROL SYSTEM

TROUBLE SHOOTING THE GAS CONTROL SYSTEM

HONEYWELL MILLIVOLT VALVE

START

¥ GAS SUPPLY ON

YES

PILOT LIGHTS WITH PIEZO IGNITOR

YES

PILOT STAYS LIT

YES

PILOT LIGHTS MAIN BURNER

YES

SYSTEM OK.

 

 

 

 

 

CHECK

NO

 

 

 

¥ SUPPLY LINE HOOKED UP

 

 

 

 

 

 

 

¥ SHUTOFF VALVE OPEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

¥ LOCKOUT HAS ENGAGED. WAIT

 

 

 

 

 

60 SECONDS AND TRY AGAIN.

 

 

 

 

 

¥ FOR SPARK AT ELECTRODE

 

 

 

 

 

WHILE DEPRESSING PIEZO

 

 

 

 

 

Ñ 1/8" GAP TO

NO

 

 

 

 

PILOT HOOD NEEDED.

 

 

 

¥ALL WIRING CONNECTIONS

¥REPLACE PIEZO IGNITOR

¥FOR AIR IN THE LINES

¥THERMOPILE NEEDS A MINIMUM 325mV. ADJUST PILOT FLAME HEIGHT.

¥ALL WIRING CONNECTIONS.

NO HONEYWELL MILLIVOLT VALVE ¥ REPLACE THERMOPILE

¥THERMOCOUPLE NEEDS A MINIMUM OF 14mV.

¥DEFECTIVE VALVE. TURN TO PILOT, METER SHOULD READ GREATER THAN 100 mV. IF NOT, REPLACE.

¥VALVE IS TURNED ON

¥ON/OFF SWITCH IS NOT

TURNED ON. WATCH

NO START FOR GROUNDED WIRES!

¥THERMOPILE NEEDS A MINIMUM 325mV.

¥PLUGGED BURNER ORIFICE.