Vermont Casting BHDR36 General Information On Assembling, The Vent Pipes With Crimped Ends

Models: BHDR36

1 36
Download 36 pages 8.11 Kb
Page 9
Image 9
Termination Clearances

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

Inside Corner

Outside Corner

Recessed Location

 

 

 

B =

 

A =

 

Combustible

A

Combustible

 

6"(152mm)

 

 

 

6"(152mm)

V

Noncombustible

 

Noncombustible

2"(50mm)

 

 

V

2"(50mm)

B

 

Balcony -

 

Balcony -

 

with no side wall

 

with perpendicular side wall

 

G

H

 

 

 

 

 

V

 

V

 

 

Combustible &

J

G =

 

 

 

Non-Combustible

 

Combustible&

 

 

 

 

 

Non-Combustible

H = 24"(610mm)

 

12"(305mm)

 

J = 20"(508mm)

 

 

 

 

Inside CornerOutside Corner D Recessed LocationBalcony -

CC

with no side wall E with perpendicular side wall

V

C = Maximum depth of 48" (1219mm) for recessed location.

D = Minimum width for back wall of a recessed location. Combustible 38"(965mm) Noncombustible 24"(610mm)

E = Clearance from corner in recessed location. Combustible 6"(152mm) Noncombustible 2"(50mm)

Fig. 11

GENERAL INFORMATION ON ASSEMBLING

THE VENT PIPES WITH CRIMPED ENDS

Before joining elbows and pipes apply a bead of high temperature sealant to crimped end of elbow or pipe. (Fig.12) Join pipes and secure joints with three (3) sheetmetal screws. (See Fig. 12) Wipe off excess sealant.

BEAD LOCATION

1" FROM CRIMPED END OF PIPE

 D 1''GENERAL INFORMATION ON ASSEMBLING

Screw Holes

Fig. 12

- 9 -

Page 9
Image 9
Vermont Casting BHDR36 General Information On Assembling, The Vent Pipes With Crimped Ends, Termination Clearances, D Cc E