REAR VENTING APPLICATIONS
Note: It is not necessary to seal the vent pipe joints for any rear vent applications.
Minimum clearances between vent pipe and com- bustible materials are as follows:
Top | - 2" (50 mm) |
Sides | - 1" (25 mm) |
Bottom | - 1" (25 mm) |
Note: Vent Starter Kit Model 7DVRVT must be used in rear vent applications.
Maximum Vent Length | 20" - Fig. 13 |
Fig. 13
20" (508mm)
TOP VIEW
REAR WALL INSTALLATIONS
Minimum clearance between vent pipes and combustible materials in one (1") inch (25
mm)on sides and bottom and two (2") inch (50 mm) on top.
STEP 1
Locate vent opening on wall.
Vent Opening —
Combustible Wall
(240mm)
(framing detail)
Vent Opening —
Noncombustible Wall
Fig. 14
Combustible Walls. Cut a
STEP 2
Measure wall thickness and cut adjustable zero clearance sleeve parts to proper length (MAXIMUM 12"). Adjust sleeve to maximum
| Maximum Length | #8 | |
| SCREWS(2) | ||
| 12" (294mm) | ADJUSTABLE | |
| #8 | ||
| ZERO CLEARANCE | ||
SCREWS(2) | |||
SLEEVE | |||
|
| ||
| #8 |
| |
| SCREWS(2) |
| |
Fig. 15 | ADJUSTABLE ZERO |
| |
| CLEARANCE SLEEVE |
| |
| FIRESTOP |
|
STEP 3
Measure from fireplace collar face to face of outside wall (add 2" for vent pipe overlap). Mark pipes and cut to length. It is very important that the two pipes are flush with the outside wall once the fireplace is in its final location. Fig. 16.
STEP 4
Slip 4" and 7" pipes onto respective flue collars. Make sure to fix to the fireplace collar the 4" pipe with three (3) screws before fixing the 7" pipe on the 7" collar. Both pipes must be on a level plane. Fig. 17.