Vermont Casting BHDR36 Final Finishing, Hearth, Gas Specifications, Certified To

Models: BHDR36

1 36
Download 36 pages 8.11 Kb
Page 6
Image 6
FINAL FINISHING

FINAL FINISHING

Non-combustible materials such as brick and tile can be extended over the outer face of the unit (Do not cover louvres or glass door). If a Trim Kit is going to be installed, brick and tile will have to be installed flush with the side of this appliance.

HEARTH

A hearth is not mandatory but it is recommended for aesthetic purposes. We recommend a non-combustible hearth which does not obstruct louvre opening.

Cold climate installation recommendation: When installing this unit against a non- insulated exterior wall or chase, it is mandatory that the outer walls be insulated to conform to applicable insulation codes.

GAS SPECIFICATIONS

 

 

 

 

MAX.

MIN.

 

 

 

 

INPUT

INPUT

MODEL

FUEL

GAS CONTROL

B.T.U.H

B.T.U.H.

BHDR36 RN

Natural Gas

Millivolt

Hi/Lo

18,000

12,600

BHDR36 RP

Propane Gas

Millivolt

Hi/Lo

18,000

13,500

 

 

 

 

 

 

GAS INLET & MANIFOLD PRESSURES

 

NATURAL

LP (Propane)

Input Minimum

4.5" wc

11" wc

Input Maximum

7" wc

13" wc

Manifold Pressure

3.5" wc

10" wc

CERTIFIED TO

ANSI Z21.88a-1998 / CSA 2.33a-M98

Vented Gas Fireplace Heaters

Do not use this fireplace if any part of it has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control which has been under water.

The installation of your Majestic Fireplace must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1 latest edition, or CAN

1B1-149.1 and .2 Installation Code. (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5 inches W.C. for Natural Gas and 10 inches W.C. for LP gas.)

- 6 -

Page 6
Image 6
Vermont Casting BHDR36 Final Finishing, Hearth, Gas Specifications, Gas Inlet & Manifold Pressures, Certified To