LIGHTING AND OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This fireplace has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly.

B.BEFORE LIGHTING smell all around the fireplace area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace.

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this label

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to off position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn clockwise

to "OFF". Do not force.

LO

HI

it

N

 

OFF

 

 

 

O

 

F

 

PILOT

T

P

OF

 

 

OLI

 

 

EURO SIT

SIT NOVA

HONEYWELL

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal in manual).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to "PILOT".

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

OR

If knob does not pop up when released, stop and immediately call your service technician or gas

supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to "On" position.

13.For Rn/RP appliances turn the On/Off switch to "On" positin or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

TO TURN OFF GAS TO FIREPLACE

1.

Turn the On/Off switch to Off position or set the

4.

Push in gas control knob slightly

 

thermostat to lowest setting.

 

and turn clockwise

to

2.

Turn off all electric power to the fireplace if service

 

"OFF". Do not force.

 

 

is to be performed.

5.

Close control access panel.

 

3.Open control access panel.

- 30 -

Page 30
Image 30
Vermont Casting BHDR36 installation instructions Lighting and Operating Instructions

BHDR36 specifications

The Vermont Casting BHDR36 is a versatile and high-performing gas fireplace that seamlessly blends efficiency with style. This fireplace is distinguished by its 36-inch width and offers an impressive heat output, making it an ideal choice for both heating purposes and aesthetic appeal in any home setting.

One of the standout features of the BHDR36 is its innovative burner technology. The fireplace utilizes a dual burner system that ensures a consistently high efficiency rating, generating ample warmth while minimizing gas consumption. This is particularly beneficial for homeowners looking to reduce energy costs while enjoying a cozy ambiance.

The design of the BHDR36 is equally impressive. It features a large, tempered glass viewing area that allows for a panoramic view of the mesmerizing flames. This expansive glass front not only enhances the aesthetic appeal but also improves the overall heating performance by providing greater radiant heat distribution throughout the room. The minimalist design complements various interior styles, making it an excellent addition to both traditional and contemporary spaces.

Furthermore, the BHDR36 is equipped with Vermont Castings’ advanced heating technologies, including a built-in fan that circulates warm air effectively and evenly throughout the space. This ensures that every corner of the room receives warmth, eliminating cold spots and enhancing comfort during the colder months.

Ease of use is another hallmark of the BHDR36. It features a convenient remote control that allows users to adjust the flame height and heat settings with ease. The fireplace’s electronic ignition system ensures a reliable start-up every time, and the adjustable flame allows for a customizable experience based on individual preferences.

Safety is paramount, and Vermont Castings has designed the BHDR36 with this in mind. It includes features such as a safety shut-off valve and a protective screen to prevent accidental contact with the flames. These safety elements provide peace of mind for families and pet owners alike.

In summary, the Vermont Casting BHDR36 is a perfect combination of cutting-edge technology, stylish design, and user-friendly features. With its efficient heating capabilities, extensive viewing area, and significant attention to safety, it stands out as a top choice for homeowners looking to enhance their living spaces with a reliable and beautiful gas fireplace.