| PROBLEM |
| SOLUTIONS (Follow Sequentially) |
|
|
|
| ||
| Water always filling. |
| a.Clean sensors thoroughly with brush and vinegar. |
|
|
|
| b.Adjust the sensitivity of the B Board (for the top sensor) fully clockwise. |
|
|
|
| c. If filling persists, ground out the top sensor (if filling stops, replace sensor – |
|
|
|
| Part #010212). |
|
|
|
| d.If filling persists after grounding out the sensor, replace the B Board (Part |
|
|
|
| #001166) |
|
| Water never fills. |
| a.Turn water switch (far right) ‘ON.’ |
|
|
|
| b.Clean sensors thoroughly with brush and vinegar. |
|
|
|
| c. Adjust the sensitivity of the B Board (for the top sensor) fully |
|
|
|
| counterclockwise (follow instructions on sheet). |
|
|
|
| d.Remove the wire from the top sensor. If filling begins, replace the sensor |
|
|
|
| (Part #010212). |
|
|
|
| e.If water does not fill, place a jumper wire across terminals A & C on the B |
|
|
|
| Board. If filling begins, replace B Board (Part #001166). |
|
|
|
| f. If water does not fill, replace water solenoid (Part #008133). |
|
| Runner bar will not light. |
| a.Remove and clean the flame switch bulb in the runner bar, enabling it to get |
|
|
|
| red hot. |
|
|
|
| b. Reposition flame switch bulb in the runner bar, enabling it to get red hot. |
|
|
|
| c. Replace flame switch (Part #004311) |
|
| Timers counting down in the |
| a.Reset the timer (see instructions on page 9) |
|
| wrong mode (Not minutes and |
|
|
|
| seconds). |
|
|
|
| Water leaking in the rear of the |
| a.Replace fill hose (Part #033495 – Sold per foot) |
|
| Custom Pasta System. |
|
|
|
| Burners won't come on (gas |
| a.Verify operating instructions in this manual (See page 9) |
|
| runner bar may be lit). |
| b.Clean the sensors with brush and vinegar. |
|
|
|
| c. Adjust sensitivity of the A Board (for the lower sensor) fully |
|
|
|
| counterclockwise (follow instruction sheet). |
|
|
|
| d.Place the wire attached to the lower sensor to ground. If heating begins, |
|
|
|
| replace the sensor (Part #010212). |
|
|
|
| e.If heating does not begin, place a jumper wire across terminals A & C on |
|
|
|
| the A Board. If heating begins, replace the A Board (Part #001167). |
|
| Unit is out of power. |
| a.Check electrical connection. |
|
|
|
| b.Check fuses. |
|
|
|
| c. Check |
|
| Unit is powered, runner bar |
| a.Check gas connection. |
|
| cannot be started. |
| b.Check the gas valve. |
|
|
|
| c. Check the spark ignition electrode and spark ignition module if there is no |
|
|
|
| spark on the electrode. |
|
| Runner tube is starting, but |
| a.Clean flame sensor switch. |
|
| cannot hold the flame. |
| b.Check electrical connection to the flame switch. |
|
|
|
| c. (spark ignition only) Check spark ignition electrode. |
|
|
|
| d.(spark ignition only) Check electrical grounding. |
|
|
|
|
|
|
|
|