6
SERIES 2000 TS MODELS
OPERATING INSTRUCTIONS
TS CONTROL PANEL – SERIES2000
START-UP PROCEDURE
WARNING: DO NOT START FRYER WITHOUT
FIRST FILLING FRY POT.
STEP 1. Set "MELT-IDLE-FRY" switch to "IDLE"
position and thermostat to the "OFF"
position.
STEP 2. Turn "MAINPOWER" switch to "ON"
position. Its green light and the timers will
come on.
STEP 3. Light constant pilot located on left side of
pilot runner tube.
STEP 4. Hold the "PUSH TO LIGHT" switch for 30
seconds. The pilot runner tube will light.
STEP 5. Set thermostat to desired temperature.
STEP 6. Set "MELT-IDLE-FRY" switch to "FRY" with
oil in the fry pot. The burners will come on.
Select "MELT" with solid shortening until
liquid shortening is 1" from full mark then
switch to the "FRY" position after packing
shortening around burner tubes.
SHUTDOWN PROCEDURE
STEP 1. Set thermostat to the "OFF" position.
STEP 2. Turn "MAIN POWER" switch to the "OFF"
position. Its green light will go off.
STEP 3. Turn gas supply valve to the "OFF" position.
STEP 4. Check to make sure all burners and pilot are
extinguished.
SERIES 2006 TS MODELS
OPERATING INSTRUCTIONS
TS CONTROL PANEL - SERIES2006
TS CONTROL PANEL - SERIES2009
START-UP PROCEDURE
WARNING: DO NOT START FRYER WITHOUT
FIRST FILLING FRY POT.
STEP 1. Set thermostat to the "OFF" position.
STEP 2. Turn "MAINPOWER" switch to "ON"
position. Its green light and the timers will
come on.
STEP 3. Light constant pilot located on left side of
pilot runner tube.
STEP 4. Hold the "PUSH TO LIGHT" switch for 30
seconds. The pilot runner tube will light.
STEP 5. Set thermostat to desired temperature.
STEP 6. Set "MELT-IDLE-FRY" switch to "FRY" with
oil in the fry pot. The burners will come on.
Select "MELT" with solid shortening until
liquid shortening is 1" from full mark then
switch to the "FRY" position after packing
shortening around burner tubes.
SHUTDOWN PROCEDURE
STEP 1. Set thermostat to the "OFF" position.
STEP 2. Turn "MAIN POWER" switch to the "OFF"
position. Its green light will go off.
STEP 3. Turn gas supply valve to the "OFF" position.
STEP 4. Check to make sure all burners and pilot are
extinguished.
SERIES 2009 TS SPARK IGNITIONMODELS OPERATING INSTRUCTIONS
TS SPARK IGNITION CONTROL PANEL SERIES2006
TS SPARK IGNITION CONTROL PANEL SERIES2009
START-UP PROCEDURE
WARNING: DO NOT START FRYER WITHOUT
FIRST FILLING FRY POT.
STEP 1. Set thermostat to the "OFF" position.
STEP 2. Turn "MAINPOWER" switch to "ON"
position. Its green light and the timers will
come on.
STEP 3. Set thermostat to desired temperature.
STEP 4. Set "MELT-IDLE-FRY" switch to "FRY" with
oil in the fry pot. The burners will come on.
300
275
A
L
O
T
C
250
350
D
T
R
A
I
B
T
H
S
E
I
F
I
A
L
375
325
MELT - FRYPOWER POWER ON PILOT ONPILOT
T3T2
SET
T1
1-800-KEATING
T3T2
SET
T1
1-800-KEATING