Thermostat Bulb Positioning 10×11, 18 & larger
Fryer Gas
DO NOT ADJUST THERMOSTAT SET SCREW - IT
VOIDS ANY WARRANTY ON PART
WARRANTY REPAIRS
Keating's warranty begins with the date of
installation. In the event that your Fryer, under
warranty, needs repairs other than routine cleaning,
you are required to contact
KEATING OF CHICAGO, INC. (1-800-KEATING)
before calling a local service company.
SERVICE
Servicing should only be performed by qualified and
licensed service companies.
THERMOSTAT REQUIRED TEST EQUIPMENT:
Multimeter (for testing continuity)
CHECKING CONTINUITY WITH THE MULTIMETER
1. Rotate the thermostat shaft until an audible click
is heard.
2. Rotate the thermostat shaft left and right ten
times causing the switch to click on and off ten
times, while using the Multimeter to verify
continuity.
3. If the switch does not show continuity during all
ten trials, replace the thermostat.
DISASSEMBLING THE THERMOSTAT WILL VOID
THE THERMOSTAT WARRANTY.
1. Set compression ring onto capillary end of bulb
finger tight, 1/2" from end of capillary.
2. Insert new thermostat bulb through control panel
back.
3. Apply oil resistant flexible sealant onto
compression fitting thread before installing fitting
into fryer vessel.
4. Position bent portion of bulb against far right heat
transfer tube and install compression fitting
snugly into fryer vessel.
5. Adjust bulb so at least 2" of bent portion of it is
next to heat transfer tube and tighten
compression nut onto compression fitting for
fryer 10x11, 18 & up. The end of thermostat bulb
should touch the burner tube for 14" fryers.
6. Replace burners.
7. Replace control panel back.
8. Slide back fabric shield over capillary and
carefully coil capillary. Avoid crimping.
9. Reconnect wires to thermostat body.
10. Replace two screws which hold thermostat body
to control panel.
11. Replace control panel.
12. Replace three retaining screws and washers
which hold dial plate in place.
13. Replace thermostat knob.
14. Connect electric power source. Turn on gas and
pilots.
15. Boil out fryer.
16. Refill fryer with oil to Max line.
17. Start fryer, preheat and calibrate with
thermometer.
TROUBLESHOOTING

Millivolt Gas Valves

Part # 023625 (natural) & 023624 (LP)

MILLIVOLT CONTROL VALVE

To check Resistance of the gas valve, connect one
wire to the valve as shown.
1. Resistance between the THTP & TH terminals
must be 11.5±0.2
2. Resistance between the THTP & TP terminals
must be 10.0±0.2
If resistance is outside of specifications listed, the gas
valve must be replaced.
Before replacing thermopile check millivolt
readings.
THERMOPILE READINGS:
With all wires connected, with the pilot on and burners
off, the thermopile reading at the TP&THTP terminals
should be ~500mv. With the burners on, the millvolt
reading should be ~200mv. Areplacement thermopile
part # is 022770.
12