Installation Instructions (cont'd)
Filling the Water Heater
ACAUTIONI
Never usethis water heat_'unlessit mcompletelyfilledwith I
wa_. To_ont dam_eto thetank,thetankmustbeelk_ I
with water. Water must flow from the hot water faucet
beforeturning "ON" gasto the water hea_.
To fill the water heater with water:
•Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater.
Open the cold water supply valve to the water heater. NOTE: The cold water supply valve must be left open when the water heater is in use.
To insure complete filling of the tank, allow air ro exit by
opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the
water heater and the piping.
Check all new water piping for leaks. Repairas needed.
Venting
_E,WARNING
VENT DAMPERS- Any vent damper, whether it is operated thermally or otherwisemustbe remom_lif itsuseinhibitsprop- er draftingof the waterheater.
Thermally Operated Vent Damper_
Vent dampersmust bear evidenceof certificationascomplying with the latestedition of American National StandardANSI
Z21.68 (ANSI 7.21.66& 67, respectively,coverelectricallyand mechanicallyactuatedvent dampers).Beforeinstallationof any ventdamper,consultyourlocalSearsServiceCenteror thegas utilityfor further information.
AWARNING
To insure proper venting of this
For proper venting in certain installations, a largerdiameter vent pipe may be necessary. Due to great variances in installations,
venting for your water heater from the vent tables in the latest edition of the National Fuel Gas Code ANSI Z223.1, also
referred to as NFPA 54.
Check the venting system for signs of obstruction or deteriora- tion and replace if needed.
The combustion and ventilation air flow must not be obstructed.
,AWARNING
Ob .structedor deterioratedventsystemsmaypresenta serious
Ihealthrisk or asphyxiation.
•Place the draft hood legs in the receiving holes on the top of the water heater. The legs will snap in the holes to give a tight fit.
•Place the vent pi.pe over the draft hood. With the vent pipe in position, drill a small hole through both the vent pipe and draft hood. Secure them together with a sheet metal screw.
DRAFT HOOD | t | _VEN T,,,,] |
, | _ | ISCREV¢____DRAFTHOODI |
DRAFT HO_TNTOOUTDOORS OR
AWARNING
The water heater wit_lledmust be properlyI vented to a chimneywhichterminatesoutdoors.Never oper- ate the water heater unlessit isventedto the outdoorsand has
adequateair supplyto avoidrisksof improperoperation,explo-
sionor esphyxiation.[
AWARNING[
The vent pipefrom the water heater mustbe no lessthan the I diameter of the draft hoed outlet on the water heater, and must slopeupwardto the chimneyat least'/4inchper linear foot
13