Installation Checklist

Installation Instructions

Installation Checklist

BEFORE LIGHTING THE PILOT:

Check the gas lines for leaks.

a. Use a soapy water solution. DO NOT test for gas leaks usinga match or open flame.

b. Brush the soapy water solution on all gas pipes, joints and

fittings.

c. Check for bubbling soap. This means you have a leak. Turn OFF _ gas andmake the necessary repairs.

d.Recheck for leaks.

e.Rinse offsoapy solution and wipe dry.

Is the new temperature-pressure relief v_ve properly installed

(cont'd)

VENT

PIPE TO

OUTDOORS

OR CHIMNEY

HOT

COLD

 

UNION SHUTOFF VALVE

HOT-

• COLD

and piped to an adequate drain? See Temperature-Pressure Relief Valve section.

Are the cold and hot water lines'connected to the water

heater correctly? See "Water Pip_ng" instructions in the c Installat . on Instruct . ons. section. .

Is the water heatercompletely filled with water? See _Filling" instructions in the Installation Instructions.

Will a water leak damage anything? See the "Facts to Consider About the Location section.

Is there proper clearance between the water heater and any-

thing that m!ght catch fire?See the "Facts to Consider About the Location section.

Do you have adequate ventilation so that the water heater

will operate properly? See _Corabustion Air and Ventilation" in the "Facts to Consider About the Location" section,

Is the draft hood vent piping properly secured? See _Venting" instructions in the "Installation Instructions" section.

Is there proper clearance between the vent pipe and anything

that might catch on fire? See "Venting" instructions in the

"Installation Instructions" section. "

Is the vent pipeproperty sloped and does the vent terminate

outdoors? See "Venting" instructions in the "Installation Instructions" section.

Do you need to call your gas company to check the gas pipe and its hookup?

2

PRESSURE

RELIEF VALVE

GAS SUPPLY

DISCHARGE PIPE (Do not cap or plug)

SHUTOFF

VALVE

TEE,

DRIP LEG

DRAIN VALVE

TRAP)

PIPE CAP

6 INCH AIR GAP

FLOOR DRAIN

CHECK FOR LEAKS

Be sure to check all your gas pipes for leaks before lighting your

water heater. Use a soapy water solution, not

a match or open

MODEL RATING PLATE

flame. Check the factory gas fittings after pilot

is lit and gas con-

 

trol knob is still in "PILOT" position. Then,

check the fittings

 

when the main burner is turned "ON". Use a soapy water solu- tion for this, too.